IEC Magnetic Contactors

Electromagnetically operated switching contactors built to IEC 60947-4-1 standards, used to switch motor and power loads on and off under electronic or manual control. Search by AC rating, coil voltage or pole configuration, or describe your motor load and let ChatMRO match the contactor.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a IEC Magnetic Contactor?

A magnetic contactor is an electromechanical switch that uses a coil-energized electromagnet to pull a set of main contacts closed, switching a motor or power circuit on and off under remote or automatic control, and opening again (via spring return) when the coil is de-energized. IEC 60947-4-1 defines the rating system used internationally (as opposed to NEMA sizing common in North America), and contactors are rated by utilization category — AC-3 for standard squirrel-cage motor starting/stopping duty, AC-1 for non-inductive/resistive loads — since the same current rating means different real-world capability depending on the load type being switched.

Coil voltage (AC or DC, commonly 24V, 120V, 240V) must match the control circuit supplying it, and is independent of the main contact's power circuit voltage/current rating. Contactors are frequently paired with a separate thermal or electronic overload relay to form a motor starter (protecting the motor from sustained overcurrent, which the contactor alone doesn't provide), and auxiliary contact blocks add extra normally-open/normally-closed contacts for interlocking, indication or control logic beyond the main power switching function.

Prefer a quick quote?

Get IEC Magnetic Contactors Pricing in Your Inbox

Skip the search — tell us the motor HP/current rating, coil voltage and pole configuration and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Utilization CategoryAC-1 (resistive), AC-3 (motor start/stop), AC-4 (jogging/reversing)Determines real-world switching capability — the same current rating handles less power under AC-3/AC-4 duty than AC-1
Contactor RatingRated current (A) at a given voltage, per IEC 60947-4-1Must be sized to the motor's full-load current with appropriate margin, not just nameplate HP
Coil VoltageCommon: 24VDC, 24VAC, 120VAC, 240VACMust match the control circuit voltage supplying the coil — independent of the main contact power rating
Pole Configuration1, 2, 3, or 4-pole3-pole is standard for 3-phase motor switching; additional poles used for special control schemes
Mechanical/Electrical LifeRated in operating cycles at rated loadHigher-cycle applications (frequent start/stop) need contactors rated for the expected duty cycle

Shop IEC Magnetic Contactors

Browse IEC Magnetic Contactors Sub-Categories

Organised by contactor application. Pick a sub-category, or tell ChatMRO your motor rating and coil voltage and it will match the right contactor.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where IEC Magnetic Contactors Get Used

IEC magnetic contactors are specified anywhere a motor or power load needs to be switched under remote, automatic or control-system command rather than by a manual disconnect.

Motor Control Centers (MCCs)

Contactors switching individual motor starter buckets within centralized motor control centers in industrial facilities.

HVAC Equipment Control

Switching compressor, fan and pump motors in commercial and industrial HVAC equipment.

Pump & Compressor Control Panels

Motor switching in pump station and air compressor control panels across water, wastewater and industrial applications.

Machine Building & OEM Equipment

Contactor-based motor and power switching integrated into custom industrial machine control panels.

Lighting & General Power Switching

Contactors switching large lighting loads and general power circuits in commercial and industrial buildings.

Elevator & Conveyor Control Systems

Reversing contactor pairs controlling motor direction in elevators, conveyors and material handling drive systems.

FAQ

IEC Magnetic Contactors Questions, Answered

What's the difference between AC-1 and AC-3 utilization category ratings?

AC-1 covers non-inductive or slightly inductive loads (like resistive heating), where the contactor mainly switches a steady current with minimal inrush. AC-3 covers standard squirrel-cage motor starting and stopping, which involves a high inrush current at start and breaking the motor's running current — a contactor rated for a given current under AC-1 will generally handle less motor horsepower under AC-3 duty at that same current rating, so always check the AC-3 rating specifically when sizing for motor control.

How do I size a contactor for my motor?

Match the contactor's AC-3 rated current to the motor's full-load amperage (FLA) from the motor nameplate, not the motor's horsepower rating alone, since FLA varies with voltage and motor design. Many engineers also apply a margin above FLA and verify against the contactor manufacturer's published motor horsepower chart for the specific voltage and duty cycle.

Do I need a separate overload relay, or does the contactor protect the motor from overcurrent?

A contactor by itself only switches the circuit on and off — it does not provide overcurrent or thermal overload protection for the motor. A separate thermal or electronic overload relay, sized to the motor's FLA, is required in series with the contactor to form a complete motor starter that trips and opens the circuit if the motor draws sustained excessive current.

Can I use a 24VDC coil contactor with a PLC output, and how is that different from an AC coil?

Yes — 24VDC coil contactors are commonly used with PLC digital outputs since many PLCs output 24VDC control signals directly, avoiding the need for an interposing relay. AC coil contactors (120V/240V) are used when switched directly from an AC control circuit, such as a relay or switch on line voltage; coil voltage must match your actual control circuit voltage, not the power circuit being switched.

What's a mechanically interlocked reversing contactor pair, and why is it needed?

A reversing contactor pair uses two contactors wired to swap two motor phases, reversing motor direction — mechanical interlocking physically prevents both contactors from closing simultaneously (which would create a phase-to-phase short circuit), providing a hardware safeguard in addition to any control-logic interlocking. This mechanical interlock is standard practice, not optional, on any reversing contactor application.