Electric Actuated Ball Valves

Electric actuated ball valves pair a quarter-turn ball valve with a motorized actuator for remote or automated on/off and modulating flow control. Search by pipe size, voltage, and control signal, or describe the process and let ChatMRO match the right valve.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Electric Actuated Ball Valve?

An electric actuated ball valve combines a standard quarter-turn ball valve body with an electric motor-driven actuator that rotates the ball 90 degrees between fully open and fully closed, replacing manual operation with a remote electrical signal. On/off actuators simply drive the valve fully open or fully closed on a digital signal, while modulating actuators accept an analog control signal (commonly 4-20mA or 0-10VDC) and can position the ball at any point between open and closed to throttle flow proportionally.

Actuator and valve body must be sized together — the actuator's torque rating has to exceed the valve's break-to-open and running torque at the maximum system pressure differential, and undersizing the actuator is a common cause of stalled or slow-cycling valves. Valve body material (bronze, stainless steel, PVC/CPVC) and seat material (PTFE, EPDM) should be selected for the actual media and temperature, since an actuator failure is often really a valve seat compatibility problem showing up as excess operating torque.

Prefer a quick quote?

Get Electric Actuated Ball Valves Pricing in Your Inbox

Skip the search — tell us the pipe size, voltage and on/off or modulating control and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Control SignalOn/off (digital) vs. modulating (4-20mA, 0-10VDC)Determines whether the valve only fully opens/closes or can throttle to any intermediate position
Actuator TorqueRated torque vs. valve break-to-open torqueUndersized actuator torque causes stalling or incomplete valve travel at rated pressure
Voltage24VAC/DC, 120VAC, 230VACMust match available control/power voltage; also affects actuator size and cost
Body MaterialBronze, stainless steel, PVC/CPVCSelected for media compatibility, pressure rating and corrosion resistance
Cycle TimeSeconds per 90-degree strokeFast-cycling actuators suit process control; slow-cycling reduces water hammer in liquid lines

Shop Electric Actuated Ball Valves

Browse Electric Actuated Ball Valves Sub-Categories

Organised by control type. Pick a sub-category, or describe the process and control signal and let ChatMRO match the valve.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Electric Actuated Ball Valves Get Used

Electric actuated ball valves are specified anywhere flow needs to be controlled remotely or automatically rather than by manual operation.

HVAC & Building Automation

Modulating control of chilled and hot water flow integrated with building management systems.

Water & Wastewater Treatment

Automated on/off and throttling control of process and distribution flow.

Industrial Process Control

Remote-controlled valves integrated into PLC and SCADA-based process automation.

Irrigation & Agriculture

Automated zone control valves for scheduled or sensor-triggered irrigation.

Fire Protection & Life Safety Systems

Remotely monitored and controlled valves in supervised fire suppression piping.

Commercial Plumbing

Automated shutoff valves for leak detection and remote building water control.

FAQ

Electric Actuated Ball Valves Questions, Answered

What's the difference between on/off and modulating electric ball valve actuators?

On/off actuators drive the valve fully open or fully closed in response to a simple digital signal and cannot hold an intermediate position reliably. Modulating actuators accept a proportional analog signal (typically 4-20mA or 0-10VDC) and can position the ball anywhere between open and closed, allowing the valve to throttle flow — needed for process control loops but not for simple shutoff applications, where on/off is simpler and less expensive.

How do I make sure the actuator has enough torque for my valve?

Check the valve manufacturer's rated break-to-open and running torque at your system's maximum pressure differential, then select an actuator with a rated torque that exceeds that figure with margin — torque requirements increase with valve size and system pressure, and can be higher than expected on valves that have sat in one position for extended periods. An undersized actuator will stall, cycle slowly, or fail to fully seat the valve.

Can I use a ball valve actuator with a different brand of valve body?

Many actuators mount via a standard ISO 5211 flange pattern and use a splined or square valve stem, making them interchangeable across brands within that standard — but always confirm the actuator's mounting pattern, stem engagement, and torque rating match the specific valve body before pairing them, since not every valve follows the same mounting standard.

What voltage should I choose for an actuated ball valve?

This is driven by what control and power voltage is already available at the installation point — 24VAC/VDC is common in building automation and low-voltage control systems, while 120VAC or 230VAC actuators are used where line voltage is readily available and a separate low-voltage supply isn't already in place. Confirm the actuator's voltage matches the control system output as well as the available power source.

How does cycle time (actuator speed) affect valve selection?

A fast-cycling actuator (a few seconds per 90-degree stroke) suits process applications needing quick response, but on larger liquid lines a very fast valve closure can cause water hammer — pressure spikes from the sudden stop of flowing liquid. Slower-cycling actuators are often specified deliberately on larger liquid lines to close gradually and avoid that pressure surge.