Browse by category

Solenoid Air Control Valves

Solenoid-actuated pneumatic control valves in 2-way, 3-way and 4-way configurations. Search by voltage and port size, or describe the actuator being controlled.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Solenoid Air Control Valve?

A solenoid air control valve is an electrically actuated pneumatic valve that uses a coil-driven plunger to shift a spool or poppet, switching compressed air between ports without any manual or mechanical linkage. Porting configuration is the first thing to specify: a 2-way valve simply opens or blocks one flow path, a 3-way valve adds a dedicated exhaust so a single-acting actuator can be actively vented on retract, and a 5-way (5/2 or 5/3) valve has two working ports and two exhausts, letting it drive a double-acting cylinder in both directions — the 5/3 variant adds a center position that can hold the actuator or block/exhaust both ports when de-energized.

Beyond porting, the valve's normally open (NO) vs. normally closed (NC) state defines fail-safe behavior with no power applied, coil voltage (12VDC, 24VDC, 110VAC, 220VAC being the common options) must match the control voltage actually present at the panel, and the Cv flow coefficient — not port size alone — determines how much air the valve can pass at a given pressure drop, which is what actually governs actuator cycle speed.

Prefer a quick quote?

Get Solenoid Valve Pricing in Your Inbox

Skip the search — tell us the porting, voltage and NO/NC and we'll come back with pricing.

SpecWhat It MeansWhy It Matters
Porting2-way, 3-way, 5-way (5/2, 5/3)Matches valve to actuator type — on/off, single-acting with exhaust, or double-acting with directional control
Port Size1/8″, 1/4″, 3/8″ NPT/BSPPSets the physical fitting and connection to supply and actuator lines
Coil Voltage12VDC, 24VDC, 110VAC, 220VACMust match available control voltage — wrong voltage fails to actuate or burns out the coil
NO vs. NCNormally open or normally closed at restDetermines the fail-safe state of the circuit when power is lost
Cv RatingFlow coefficient at a given pressure dropGoverns actual flow capacity and actuator cycle speed — more reliable than port size alone

Shop Solenoid Air Control Valves

Browse Solenoid Air Control Valves Sub-Categories

Organised by port configuration. Pick a sub-category, or describe the actuator you are controlling and let ChatMRO match a valve.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Solenoid Air Control Valves Get Used

Porting configuration, duty cycle and wash-down rating decide the right valve more than line pressure alone does.

Pneumatic Cylinder & Actuator Control

5/2 and 5/3 valves directing air to alternate sides of double-acting cylinders for powered extend and retract.

Packaging Machinery

High-cycle-rate valves switching pick, seal and fill actuators, sized by Cv to keep up with line speed.

Automotive Assembly Lines

Solenoid manifolds banking multiple stations to sequence clamping and press actuators from a shared PLC output.

Food & Beverage Processing

Wash-down rated valves with sealed coils and stainless or coated bodies for repeated caustic cleaning cycles.

Pick-and-Place Robotics

Fast-response, low-duty-cycle valves switching vacuum or gripper actuators at high cycle counts.

HVAC Damper Control

2-way and 3-way valves actuating pneumatic dampers, typically on continuous-duty coils held energized for long periods.

Process Control & Instrumentation

NC valves specified for fail-safe shutoff of process air on loss of power, matched to loop-rated coil voltages.

Brands

Solenoid Air Control Valves Brands in the Catalogue

Cross-reference freely between them — ask for an equivalent and ChatMRO shows what matches and what differs.

FAQ

Solenoid Air Control Valves Questions, Answered

How do I choose between a 2-way, 3-way and 5-way (5/2, 5/3) solenoid valve?

A 2-way valve simply opens or blocks one flow path, suited to on/off air supply to a device with its own return. A 3-way valve adds a dedicated exhaust port so a single-acting cylinder can be actively vented on retract rather than just losing supply pressure. A 5-way (5/2 or 5/3) valve has two working ports and two exhausts, letting it direct air to either side of a double-acting cylinder for powered motion in both directions — 5/3 variants add a mid-position (all-ports-blocked or exhausted) for holding an actuator in place.

Should I specify a normally open (NO) or normally closed (NC) valve?

NO and NC describe the valve's flow path with no power applied. An NC valve blocks flow until energized, which is the fail-safe choice for most machine safety circuits — losing power stops air flow and the actuator de-energizes to a safe state. An NO valve passes flow until energized to shut it off, used where the fail-safe condition requires air to keep flowing, such as some brake-release or clamping circuits.

What coil voltage and duty cycle should I check before ordering?

Match the coil to the control voltage actually available at the panel — common options are 12VDC, 24VDC, 110VAC and 220VAC — since the wrong voltage either fails to actuate or burns out the coil. Also check duty cycle: continuous-duty coils are rated to stay energized indefinitely, while intermittent-duty coils overheat and fail if held energized longer than their rated on-time, which matters for valves left actuated for extended holds.

How do I size port size and Cv rating to my flow requirement?

Port size (commonly 1/8 in, 1/4 in or 3/8 in NPT/BSPP) sets the physical connection, but the Cv flow coefficient is what actually determines how much air the valve passes at a given pressure drop. A larger port with a restrictive internal path can have a lower Cv than a smaller, better-flowing valve, so size to the actuator's required flow rate and cycle speed using Cv, not port size alone.

What are the most common solenoid air valve failure modes?

Coil burnout from wrong voltage, exceeding duty cycle, or a stuck spool forcing the coil to stay energized against resistance; seal and spool wear from cycle count, contamination or dry running without adequate lubrication in the supply air; and moisture or particulate contamination in unfiltered compressed air, which causes sluggish shifting or valves that stick in one position. Proper air filtration and matching duty cycle to the application prevent most of these.

Keep browsing

Related Categories

Explore More

Find Your Next Part Now.

Describe a part number, spec or what it does.