Backflow Preventers

Reduced pressure zone, double check valve and vacuum breaker backflow preventers for potable water protection, sized by pipe connection and hazard classification. Search by device type, pipe size or application.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Backflow Preventer?

A backflow preventer stops contaminated water from siphoning or being pushed back into a potable water supply when a cross-connection exists and system pressure drops or reverses — required by plumbing code on irrigation systems, fire sprinkler connections, boiler feeds and any connection where non-potable water could reach a drinking water line. Device selection is driven by the degree of hazard: a reduced pressure zone (RPZ) assembly provides the highest protection level, actively venting to atmosphere through a relief valve if either check valve fails, suited to high-hazard cross-connections.

Double check valve assemblies (DCVA) use two independently operating check valves for backflow protection without the RPZ's atmospheric vent, appropriate for lower-hazard (non-toxic) cross-connections such as many fire sprinkler systems. Vacuum breakers (pressure or atmospheric type) protect against back-siphonage only, not backpressure, and are the minimum protection typically accepted for irrigation and hose bib applications. Local plumbing code and the water authority's cross-connection control program dictate which device type is required for a given application — device selection is not simply a matter of pipe size.

Prefer a quick quote?

Get Backflow Preventers Pricing in Your Inbox

Skip the search — tell us the pipe size, device type (RPZ, DCVA, PVB) and application and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Device TypeRPZ, double check (DCVA), pressure/atmospheric vacuum breakerDetermined by the hazard classification of the cross-connection, per local code — not interchangeable by pipe size alone
Protection TypeBackpressure + back-siphonage (RPZ, DCVA) vs. back-siphonage only (vacuum breakers)Vacuum breakers do not protect against backpressure, which limits where they can legally be used
Pipe Size/Connection1/2in up to 10in+, threaded or flangedMust match the service line size and connection type at the point of installation
Approvals/ListingsUSC FCCCHR approved, ASSE listed, lead-free (NSF 372) compliantMost jurisdictions require devices from an approved list for potable water cross-connection protection
TestabilityRPZ and DCVA require annual field testing with test cocksCode typically mandates annual certified testing — device must have accessible test cocks for a certified tester

Shop Backflow Preventers

Browse Backflow Preventers Sub-Categories

Organised by device type. Pick a sub-category, or tell ChatMRO the hazard classification and pipe size and let ChatMRO match an assembly.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Backflow Preventers Get Used

Backflow preventers are required by plumbing code anywhere a potable water line connects to a system that could introduce contamination under reversed flow conditions.

Irrigation & Landscape Systems

Protecting potable water supply from fertilizer, pesticide and soil contamination through irrigation cross-connections.

Fire Protection Systems

Preventing stagnant fire sprinkler system water, additives, or antifreeze from backflowing into the domestic water supply.

Commercial Boiler & Process Water Feed

Protecting potable supply from boiler water treatment chemicals at makeup water connections.

Healthcare & Laboratory Facilities

High-hazard cross-connection protection at lab sinks, equipment and specialized fixtures per plumbing code.

Municipal Water Distribution

Backflow protection at service connections to industrial, commercial and irrigation customers per utility cross-connection control programs.

Brands

Backflow Preventers Brands in the Catalogue

Cross-reference freely between them — ask for an equivalent and ChatMRO shows what matches and what differs.

FAQ

Backflow Preventers Questions, Answered

What's the difference between an RPZ and a double check valve assembly?

An RPZ (reduced pressure zone) assembly has an atmospheric relief valve between two check valves that actively vents water to atmosphere if either check fails, giving the highest level of protection and making it required for high-hazard cross-connections. A double check valve assembly uses two check valves without the relief vent, providing solid backflow protection but at a lower certified hazard level, so it's typically limited to lower-hazard applications like many fire sprinkler systems.

Do vacuum breakers protect against backpressure as well as back-siphonage?

No — pressure and atmospheric vacuum breakers only protect against back-siphonage (a vacuum condition pulling contaminated water backward), not backpressure (a downstream pressure exceeding supply pressure and pushing water backward). Where backpressure is possible, code requires an RPZ or double check assembly instead.

How often does a backflow preventer need to be tested?

Most jurisdictions require annual field testing of RPZ and double check valve assemblies by a certified backflow tester, using the device's test cocks to verify each check valve and (for RPZ) the relief valve are functioning correctly — check your local water authority's specific requirement, as some hazard classes require more frequent testing.

How do I know which device type is required for my application?

Device selection is based on the hazard classification of the specific cross-connection as determined by local plumbing code and the water utility's cross-connection control program — it's not simply a function of pipe size. Consult your local code or water authority before purchasing, since installing an under-protective device can fail inspection or code compliance.

What does 'lead-free' mean on a backflow preventer, and is it required?

Lead-free per NSF/ANSI 372 limits the wetted-surface lead content of the device's brass and bronze components, and is required by federal and most state law for any device in contact with potable drinking water in the US — verify a device is certified lead-free compliant before installing on a potable water line.