Impellers, mixing shafts, chucks and stand hardware for laboratory overhead stirrers and mixers, sized to shaft diameters from 6mm to 10mm and compatible with common bench-top mixer brands. Search by impeller type, shaft length or mixer model.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Laboratory Mixer Accessorie?

Laboratory overhead stirrers and mixers are general-purpose drive units; the impeller and shaft attached to them determine what kind of mixing action actually happens in the vessel. Propeller impellers create high axial flow suited to low-to-medium viscosity liquids and blending; anchor and paddle impellers scrape close to the vessel wall for higher-viscosity fluids; turbine impellers generate strong radial shear for dispersion and emulsification work.

Shaft diameter and material must match both the impeller's bore and the mixer's chuck capacity — common lab shaft diameters are 6mm, 8mm and 10mm, with 316 stainless steel standard for chemical compatibility and PTFE coating specified where added corrosion resistance or non-stick surface is needed. Mixer stands, boss heads and clamps hold the mixer at the correct height and angle over the vessel and are sized to standard support rod diameters (commonly 13mm/16mm) rather than the mixer itself.

Prefer a quick quote?

Get Laboratory Mixer Accessories Pricing in Your Inbox

Skip the search — tell us the mixer model, shaft diameter and impeller type and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Shaft Diameter6mm, 8mm, 10mm common lab sizesMust match both the impeller bore and the mixer chuck's clamping capacity
Impeller TypePropeller, anchor, paddle, turbine, dissolver discDetermines flow pattern — axial, radial, or wall-scraping — suited to the fluid viscosity and task
Material316 stainless steel, PTFE-coated, PPDetermines chemical compatibility with the media being mixed
Shaft LengthTypically 200mm-600mmMust clear vessel depth with adequate immersion without contacting the vessel bottom
Stand Rod Diameter13mm, 16mm standard support rodBoss heads and clamps must match rod diameter, independent of mixer brand

Shop Laboratory Mixer Accessories

Browse Laboratory Mixer Accessories Sub-Categories

Organised by accessory type. Pick a sub-category, or describe your mixer model and the viscosity/volume you're mixing.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Laboratory Mixer Accessories Get Used

Mixer accessories are specified anywhere a lab overhead stirrer needs to be configured for a specific fluid viscosity, vessel size or mixing action.

Pharmaceutical R&D

Precision shaft and impeller combinations for small-batch formulation mixing where consistent shear is critical to results.

Chemical & Materials Testing Labs

PTFE-coated shafts and impellers for mixing corrosive or reactive chemical formulations without contamination.

Academic & Research Laboratories

General-purpose propeller and paddle impeller sets supporting a wide range of teaching and research mixing tasks.

Quality Control Labs

Standardized mixer/shaft/impeller setups for repeatable sample preparation across routine QC testing.

Cosmetics & Personal Care Formulation

Turbine and dissolver disc impellers for emulsification and dispersion during small-batch product development.

Brands

Laboratory Mixer Accessories Brands in the Catalogue

Cross-reference freely between them — ask for an equivalent and ChatMRO shows what matches and what differs.

FAQ

Laboratory Mixer Accessories Questions, Answered

How do I choose between a propeller, anchor and turbine impeller?

Propeller impellers generate strong top-to-bottom (axial) flow and suit low-to-medium viscosity blending and general mixing. Anchor impellers scrape close to the vessel wall and suit higher-viscosity fluids where heat transfer or preventing settling at the wall matters. Turbine impellers create strong radial shear and suit dispersion, emulsification, or breaking up particles — choose based on the fluid's viscosity and the mixing action the process actually needs, not just vessel size.

What shaft diameter does my mixer need?

Shaft diameter is set by the mixer's chuck capacity, not by preference — check the mixer's specification sheet for its rated chuck range (commonly 6mm, 8mm, or 10mm) and select impellers and shafts within that range. Using an undersized shaft in an oversized chuck risks slippage and inconsistent mixing under load.

Why would I need a PTFE-coated shaft instead of plain stainless steel?

PTFE coating adds chemical resistance beyond what 316 stainless alone provides, useful when mixing aggressive acids, bases, or solvents that could corrode or react with bare stainless over repeated exposure. It also offers a non-stick surface that eases cleaning between batches of viscous or sticky formulations.

Do mixer stands and boss heads work with any brand of mixer?

Yes, generally — stands, boss heads and clamps are sized to standard support rod diameters (commonly 13mm or 16mm) rather than being brand-specific, so a stand from one manufacturer typically accepts a mixer from another as long as the mixer's mounting rod matches the clamp's rated diameter range.

How do I know if my impeller shaft is long enough for my vessel?

Measure the vessel's working depth and ensure the shaft, once mounted in the mixer, positions the impeller at the correct immersion depth (typically submerged with adequate clearance above the vessel bottom) without the shaft coupling or mixer housing contacting the vessel rim — account for stand height adjustment range as well.