Motorized Fire and Smoke Dampers

UL 555 and UL 555S listed dampers with electric or pneumatic actuators for fire and smoke compartmentation in ducted HVAC systems, in curtain and multi-blade configurations. Search by duct size, UL rating and actuator type, or describe the fire-rated wall or floor assembly.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Motorized Fire and Smoke Damper?

A fire damper is a UL 555-listed device installed at duct penetrations of fire-rated walls, floors and shafts that closes automatically — usually via a fusible link or, on motorized units, an electric or pneumatic actuator tied to the fire alarm system — to maintain the fire-resistance rating of the assembly it penetrates. A smoke damper is UL 555S-listed and closes on signal from the smoke control system to limit smoke migration through ductwork, and a combination fire/smoke damper is tested and listed to both standards for use where a single opening requires both functions.

Dampers are classified as static (rated for use only when the connected fan system shuts down) or dynamic (rated to close against actual airflow and pressure from an operating system), and this rating — along with the damper's UL-listed maximum size, degradation temperature and leakage class — must match the actual duct velocity, pressure and fire-rated assembly it's installed in, since a mismatch voids the fire rating of the wall or floor penetration regardless of how the damper itself performs.

Prefer a quick quote?

Get Motorized Fire and Smoke Dampers Pricing in Your Inbox

Skip the search — tell us the duct size, UL rating and actuator voltage and we will come back with pricing.

SpecWhat It MeansWhy It Matters
UL ListingUL 555 (fire) / UL 555S (smoke) / combinationDamper must be listed for the specific hazard — fire, smoke, or both — required by the assembly
Actuation TypeFusible link, electric actuator, pneumatic actuatorMotorized units integrate with fire alarm/smoke control systems for active closure, not just passive melt-link response
Static vs. Dynamic RatingStatic (system shuts down) vs. dynamic (closes under airflow)Dynamic rating required where the fan system stays running during a fire/smoke event
Leakage ClassClass I, II, III per UL 555SLower leakage class required in smoke control systems with strict compartmentation requirements
Degradation Temperature250°F standard, high-temp options to 350°FDetermines when the damper closes on rising duct temperature independent of alarm signal

Shop Motorized Fire and Smoke Dampers

Browse Motorized Fire and Smoke Dampers Sub-Categories

Organised by damper type. Pick a sub-category, or describe the fire-rated assembly you're penetrating and let ChatMRO match the damper.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Motorized Fire and Smoke Dampers Get Used

Motorized fire and smoke dampers are code-mandated at ducted penetrations of every fire-rated wall, floor and shaft assembly.

Commercial HVAC Life-Safety Systems

Duct penetrations through fire-rated corridor and shaft walls in office and mixed-use buildings.

Hospitals & Healthcare Facilities

Smoke compartmentation dampers required by NFPA 92 and healthcare-specific fire codes.

High-Rise Buildings

Dynamic dampers rated to close under operating stairwell pressurization and smoke control airflow.

Data Centers & Critical Facilities

Combination fire/smoke dampers protecting fire-rated equipment room enclosures.

Educational & Institutional Buildings

Code-mandated fire damper installation at all rated wall and floor duct penetrations.

Industrial & Manufacturing Facilities

Fire dampers protecting rated separations between process areas and occupied spaces.

Brands

Motorized Fire and Smoke Dampers Brands in the Catalogue

Cross-reference freely between them — ask for an equivalent and ChatMRO shows what matches and what differs.

FAQ

Motorized Fire and Smoke Dampers Questions, Answered

What's the difference between a fire damper and a smoke damper?

A fire damper (UL 555) closes to stop fire and hot gas from spreading through a duct penetration in a fire-rated wall or floor, typically triggered by a fusible link melting at a set temperature. A smoke damper (UL 555S) closes on a signal from the smoke control or fire alarm system to limit smoke migration, independent of temperature, and a combination fire/smoke damper is listed and tested to do both.

What does 'dynamic rating' mean and when is it required?

A dynamic rating means the damper is tested and listed to close and remain closed against actual airflow velocity and pressure while the connected fan system keeps running — required whenever code or the smoke control sequence keeps air moving during a fire event. A static-rated damper is only listed for closure after the fan system has shut down, which is unsuitable for smoke control systems designed to keep operating.

Can I substitute a fire damper with a different UL listing size than my duct opening?

No. Every UL 555/555S listing specifies a maximum installed size, and installing a damper larger than its tested and listed maximum voids the fire rating of the assembly, regardless of how the damper itself performs. Always confirm the specific model's listed maximum dimensions against the actual duct opening.

How does a motorized damper integrate with the building's fire alarm system?

A motorized fire or smoke damper uses an electric or pneumatic actuator wired to the building's fire alarm or smoke control panel, so the damper closes on command from a detected alarm condition rather than waiting for a fusible link to melt — required in dynamic smoke control sequences and any system needing active, testable closure.

How often do fire and smoke dampers need to be inspected?

NFPA 80 and NFPA 105 require fire and smoke dampers to be tested for full closure and operation one year after installation, then every 4 years for most buildings (every 6 years in hospitals), and access doors must be provided at each damper location to allow this testing without duct demolition.