Technical Foundation
What Is a Circuit Breaker Accessorie?
Circuit breaker accessories are factory-engineered modules that mount to or inside a molded case circuit breaker to add functions beyond its base thermal-magnetic or electronic overcurrent tripping — a shunt trip lets an external signal (a fire alarm system, an emergency stop circuit, a protective relay) remotely trip the breaker open regardless of load current, while an undervoltage release trips the breaker automatically if control voltage drops or is lost, a common requirement for elevator and certain motor circuits.
Fit is manufacturer- and frame-specific — a shunt trip or auxiliary switch is designed for one breaker family's physical envelope and internal mechanism, so accessories are not generically interchangeable across brands or even across different frame sizes within the same brand. Auxiliary and alarm switches report breaker status (open/closed, or tripped-on-fault versus manually opened) back to a monitoring system or SCADA/BMS point, which matters for facilities needing remote visibility into breaker state without physically inspecting the panel.
Prefer a quick quote?
Get Circuit Breaker Accessories Pricing in Your Inbox
Skip the search — tell us the breaker make/model/frame size and the accessory function needed and we will come back with pricing.
| Spec | What It Means | Why It Matters |
|---|---|---|
| Function | Shunt trip, undervoltage release, aux/alarm switch, lockout | Determines what capability is added — remote trip, auto-trip on voltage loss, status reporting, or physical lockout |
| Breaker Compatibility | Manufacturer- and frame-size-specific | Accessories are not interchangeable across different breaker brands or frame sizes |
| Control Voltage | Common options: 24V, 120V, 208-240V AC/DC | Shunt trip and undervoltage release coils must match the available control circuit voltage |
| Switch Rating | Auxiliary contact current/voltage rating | Must be adequate for whatever monitoring or control circuit the switch feeds |
| Mounting Method | Internal (factory or field-installed) module | Some accessories require the breaker to be de-energized and partially disassembled to install |
Shop Circuit Breaker Accessories
Browse Circuit Breaker Accessories Sub-Categories
Organised by function. Pick a sub-category, or describe the breaker make/model and what you need it to do and let ChatMRO match the accessory.
How it works
From Half-Remembered Part Number to PO, in Three Steps.
Ask
Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.
Compare
Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.
Quote & Buy
Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.
Applications
Where Circuit Breaker Accessories Get Used
Circuit breaker accessories are specified wherever a breaker needs to do more than trip on overcurrent alone — remote signaling, automatic trip on external conditions, status monitoring, or physical lockout.
Fire & Life Safety Systems
Shunt trip breakers tied into fire alarm panels to automatically de-energize elevator or HVAC circuits on alarm.
Elevator & Escalator Equipment
Undervoltage release breakers required by code to trip automatically if control power is lost.
Data Centers & Critical Facilities
Auxiliary and alarm switches feeding breaker status back to building management and monitoring systems.
Industrial Motor Control Centers
Shunt trip and remote-trip accessories integrated with protective relay schemes for motor circuits.
Electrical Maintenance & Safety Programs
Breaker lockout devices used to physically secure breakers in the off position during LOTO procedures.
Emergency Power & Generator Systems
Motor-operated breakers and remote trip accessories used in automatic transfer and load-shedding schemes.
FAQ
Circuit Breaker Accessories Questions, Answered
What's the difference between a shunt trip and an undervoltage release?
A shunt trip requires an external signal (typically a momentary voltage pulse) to actively trip the breaker — nothing happens unless the signal is sent, making it fail-safe in the sense that loss of control power doesn't trip it. An undervoltage release does the opposite: the breaker trips automatically if control voltage drops or is lost, which is required by code on certain circuits (like elevators) where losing control power should also de-energize the load.
Can I use a shunt trip accessory from a different manufacturer on my breaker?
Generally no — shunt trips, undervoltage releases, and auxiliary switches are engineered to a specific breaker family's internal mechanism and physical mounting points, so cross-brand substitution isn't supported and in most cases won't physically fit or function correctly. Always match the accessory to the breaker's exact manufacturer, series, and frame size.
What do auxiliary and alarm switches actually report?
An auxiliary switch reports the breaker's physical position (open or closed) as a dry contact that can feed a monitoring system, PLC, or indicator light. An alarm switch specifically distinguishes a fault trip (breaker opened due to an overcurrent condition) from a manual operation, which matters for facilities that want to know not just that a breaker opened, but why, without someone physically checking the panel.
Does installing a shunt trip or auxiliary switch require de-energizing the breaker?
In most cases yes — these accessories mount inside or directly onto the breaker's case and require partial disassembly to install correctly, which means the breaker (and often the panel section it's in) must be de-energized and locked out first. This is typically a job for a qualified electrician following proper LOTO procedure, not a live-circuit modification.
Why would a facility need a breaker lockout device instead of just switching the breaker off?
Switching a breaker off doesn't prevent someone else from switching it back on — a lockout device physically covers the toggle in the off position and accepts a padlock, satisfying OSHA lockout/tagout requirements that the energy-isolating device be physically secured, not just left in the off position, during maintenance work on the downstream circuit.
Keep browsing
Related Categories
Explore More