Browse by category

Single Phase Transformers

Single phase step-up and step-down transformers sized by kVA rating and primary/secondary voltage pairing, in dry-type and oil-filled construction for control, distribution and specialty applications. Search by kVA and voltage combination, or describe the load you're powering.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Single Phase Transformer?

A single phase transformer is specified primarily by its kVA (kilovolt-ampere) capacity and its primary/secondary voltage pairing — kVA rather than kW because transformer capacity is a function of voltage and current independent of the load's power factor, and undersizing kVA relative to actual connected load causes overheating and shortened transformer life even if the load's real power (kW) looks adequately covered. Turns ratio between primary and secondary windings sets the voltage transformation, and standard voltage pairings (e.g., 480V to 240/120V, 240V to 24V control) are stocked far more readily than non-standard combinations.

Construction type affects installation requirements: dry-type transformers use air or resin insulation and are common indoors and in locations where oil-filled units' fire and environmental containment requirements would complicate installation, while oil-filled transformers offer better cooling and are common in outdoor pad-mount and higher-capacity applications. Buck-boost transformers are a special case — wired to add or subtract a smaller voltage from an existing supply (e.g., correcting 208V to 240V) rather than provide full isolation, and are sized and wired differently from standard isolation transformers.

Prefer a quick quote?

Get Single Phase Transformers Pricing in Your Inbox

Skip the search — tell us the kVA rating, primary and secondary voltage and enclosure type and we will come back with pricing.

SpecWhat It MeansWhy It Matters
kVA RatingApparent power capacity, not real power (kW)Sizing to real load's kW alone can underrate the transformer if power factor isn't accounted for
Primary/Secondary VoltageInput and output voltage pairing (e.g., 480V to 240/120V)Must match both the supply voltage and the load equipment's required voltage exactly
Construction TypeDry-type (air/resin) vs. oil-filledAffects fire rating, installation location requirements and cooling capacity at higher kVA
Enclosure RatingNEMA 1 (indoor) vs. NEMA 3R (outdoor)Determines suitability for outdoor, washdown or otherwise exposed installation
Function TypeIsolation, step-up/down, buck-boost, controlBuck-boost transformers correct/adjust voltage rather than fully isolate — wired and sized differently

Shop Single Phase Transformers

Browse Single Phase Transformers Sub-Categories

Organised by function. Pick a sub-category, or describe your primary/secondary voltage and load and let ChatMRO match the transformer.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Single Phase Transformers Get Used

Single phase transformers are specified anywhere supply voltage must be converted, isolated or corrected to match load equipment requirements.

Industrial Control Panels

Control transformers stepping panel supply voltage down to 24V or 120V for PLC and relay logic.

Commercial & Light Industrial Power Distribution

Dry-type distribution transformers converting facility supply voltage to equipment-required voltage.

Voltage Correction on Existing Supply

Buck-boost transformers correcting mismatched supply voltage (e.g., 208V to 240V) for sensitive equipment.

HVAC Equipment

Control transformers supplying low-voltage control circuits within packaged HVAC units.

Renewable Energy & Backup Power

Step-up transformers matching inverter output voltage to grid-tie or distribution requirements.

Test & Laboratory Equipment

Isolation transformers protecting sensitive test equipment from supply-side noise and providing electrical isolation.

FAQ

Single Phase Transformers Questions, Answered

Why is transformer capacity rated in kVA instead of kW?

kVA (apparent power) accounts for both voltage and current without factoring in the load's power factor, while kW (real power) reflects only the actual usable power delivered — a transformer has to handle the full current flow regardless of power factor, so sizing by kVA ensures the transformer isn't undersized for loads with a power factor below 1.0, which is common with motors and other inductive loads.

What's the difference between a step-down transformer and a buck-boost transformer?

A step-down (or step-up) transformer fully isolates the secondary from the primary and transforms voltage by a set ratio, suited to converting one voltage system to a substantially different one. A buck-boost transformer is wired to add or subtract a smaller voltage from an existing supply — correcting a slightly mismatched voltage like 208V to 240V — and does not provide the same electrical isolation, so it's not a substitute where isolation is required.

When should I choose dry-type over oil-filled construction?

Dry-type transformers are generally preferred indoors or in locations where oil containment, fire rating requirements, or environmental concerns make an oil-filled unit impractical — most commercial and light industrial indoor installations use dry-type. Oil-filled transformers offer better cooling for their size and are more common in outdoor pad-mount and higher-capacity utility-adjacent applications.

What voltage should a control transformer's secondary be?

Control transformer secondary voltage is set by what the control circuit actually needs — commonly 24V for low-voltage relay and PLC logic, or 120V for standard control circuits — and must match the rated voltage of the specific relays, contactors and control devices in the panel, not just be 'low voltage' generically. Confirm the exact secondary voltage against the panel's control circuit design.

What happens if a transformer is undersized for its connected load?

An undersized transformer runs at or above its rated kVA continuously, causing excessive heat buildup in the windings that accelerates insulation breakdown and shortens the transformer's service life, potentially leading to premature failure. Always size with margin above the actual calculated connected load, accounting for future load growth where practical.

Keep browsing

Related Categories

Explore More

Find Your Next Part Now.

Describe a part number, spec or what it does.