Browse by category

Single Gas Detectors

Single gas detectors are portable, personal monitors continuously sampling ambient air for one specific hazard gas — H2S, CO, O2, or a combustible gas — and alarming at pre-set thresholds. Search by target gas, alarm setpoints, and sensor type, or describe the exposure hazard and let ChatMRO match the right detector.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Single Gas Detector?

A single gas detector uses an electrochemical, catalytic, or infrared sensor calibrated to one specific gas, continuously sampling ambient air and triggering audible, visual, and vibration alarms when concentration crosses a pre-set low or high threshold. Electrochemical sensors dominate for toxic gases like H2S and CO because of their sensitivity and low power draw, while catalytic bead sensors are standard for combustible gas (LEL) detection, and each sensor type has a finite service life that must be tracked and replaced or the unit retired.

Detectors come in two service models: disposable units with a factory-sealed, non-replaceable sensor and battery rated for a fixed service life (commonly 2 or 3 years) that are discarded and replaced rather than calibrated, and rechargeable units with a replaceable sensor and battery that require periodic bump testing and calibration per a documented schedule. Alarm setpoints should be configured to the applicable OSHA PEL/STEL or the site's own more conservative internal limits for the specific target gas, not left at a generic factory default.

Prefer a quick quote?

Get Single Gas Detectors Pricing in Your Inbox

Skip the search — tell us the target gas and required alarm thresholds and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Target GasH2S, CO, O2, combustible (LEL)Sensor is calibrated to one specific gas — not interchangeable across gas types
Sensor TypeElectrochemical, catalytic bead, infraredDetermines sensitivity, response time, and expected sensor service life
Alarm ThresholdsLow/high alarm setpoints, STEL, TWAShould be set to OSHA PEL/STEL or the site's internal limit for the specific gas, not left at default
Service ModelDisposable (fixed life) vs. rechargeable (calibrated)Determines whether the unit is replaced on a schedule or maintained through bump testing/calibration
Alarm TypeAudible, visual (LED), vibrationMultiple alarm modes ensure detection in high-noise or dark environments

Shop Single Gas Detectors

Browse Single Gas Detectors Sub-Categories

Organised by target gas. Pick a sub-category, or describe the exposure hazard and let ChatMRO match the detector.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Single Gas Detectors Get Used

Single gas detectors are specified anywhere a worker faces exposure risk from one specific, known hazard gas.

Confined Space Entry

Continuous monitoring of O2 and toxic gas levels during entry and work inside tanks, vaults, and vessels.

Oil & Gas Production

H2S monitoring for personnel working near wellheads, tanks, and processing equipment.

Wastewater & Sewer Work

H2S and O2 monitoring for personnel entering lift stations and sewer infrastructure.

Welding & Hot Work

CO and combustible gas monitoring in enclosed or poorly ventilated work areas.

Utility & Pipeline Maintenance

Combustible gas detection during excavation and pipeline maintenance work.

Industrial Maintenance & Turnarounds

Personal gas monitoring for maintenance crews working in process areas during shutdowns.

FAQ

Single Gas Detectors Questions, Answered

Should I choose a disposable or a rechargeable gas detector?

Disposable detectors have a factory-sealed sensor and battery rated for a fixed service life (typically 2 or 3 years), require no calibration or maintenance during that period, and are simply replaced at end of life — lower hassle but higher long-term cost if used continuously. Rechargeable detectors have replaceable batteries and sensors and require periodic bump testing and calibration per a documented schedule, but can offer lower total cost of ownership for detectors in continuous daily use over several years.

What's the difference between a bump test and a calibration?

A bump test is a quick functional check exposing the detector briefly to a known gas concentration to confirm the sensor responds and the alarm triggers — it does not adjust the sensor's readings. Calibration is a more thorough process that adjusts the sensor's output against a certified reference gas to correct for sensor drift, and should be performed on a schedule set by the manufacturer or the sensor's observed drift rate.

Why does my detector need a specific sensor for each gas type?

Electrochemical and catalytic sensors are chemically or physically calibrated to respond to one target gas — an H2S sensor won't reliably detect CO, and vice versa — so the detector only protects against the specific hazard it's built and calibrated for. Where multiple gas hazards exist in the same environment, a multi-gas detector or separate single-gas units for each hazard are both used to cover the full exposure risk.

What alarm setpoints should I use for H2S or CO detectors?

Setpoints should be configured to the applicable OSHA permissible exposure limit (PEL) and short-term exposure limit (STEL) for the specific gas, or to a more conservative internal site limit if the facility's safety program specifies one — for example, OSHA's H2S ceiling limit is commonly used as a reference point for alarm configuration. Don't rely on the factory default setpoints without confirming they match the applicable regulatory or site-specific limit.

How does an oxygen (O2) detector differ from a toxic or combustible gas detector?

An O2 detector monitors for oxygen deficiency (below roughly 19.5%) or oxygen enrichment (above roughly 23.5%), both of which present distinct hazards — deficiency risks asphyxiation, enrichment increases fire risk — rather than detecting a toxic or flammable substance directly. It's a standard component of confined space entry monitoring precisely because oxygen levels can shift independently of any specific gas hazard being present.

Keep browsing

Related Categories

Explore More

Find Your Next Part Now.

Describe a part number, spec or what it does.