Browse by category

Dual Pressure Controls

Combined high/low pressure cutout switches in a single control body, protecting refrigeration and AC compressors from both excessive discharge pressure and inadequate suction pressure. Search by setpoint range and reset type, or describe the compressor and refrigerant and let ChatMRO match the control.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Dual Pressure Control?

A dual pressure control combines high-pressure and low-pressure cutout functions into a single switch body, monitoring both a refrigeration or AC system's discharge (high side) pressure and suction (low side) pressure, and interrupting the compressor circuit if either exceeds its respective safe limit. High-pressure cutout protects against condenser fouling, refrigerant overcharge, or airflow loss that would otherwise drive discharge pressure and compressor head pressure to damaging or unsafe levels; low-pressure cutout protects against refrigerant undercharge, a restricted metering device, or evaporator icing that would starve the compressor of return gas needed for motor cooling and lubricant return.

Reset type mirrors the same safety logic as other compressor protection devices — manual reset high-pressure cutouts are commonly required by code or insurance carriers, since automatically clearing a high-pressure fault and restarting could mask a genuinely dangerous condition, while low-pressure cutouts are more commonly specified with automatic reset since low-side faults (like a temporarily iced coil) are more often self-correcting. Setpoints must be selected to match the specific refrigerant's pressure-temperature relationship, since the same numerical pressure represents a different saturation temperature for different refrigerants.

Prefer a quick quote?

Get Dual Pressure Controls Pricing in Your Inbox

Skip the search — tell us the refrigerant type, setpoint range and reset type and we will come back with pricing.

SpecWhat It MeansWhy It Matters
High-Pressure Cutout FunctionTrips on excessive discharge/head pressureProtects against condenser fouling, overcharge, or airflow loss driving pressure too high
Low-Pressure Cutout FunctionTrips on inadequate suction pressureProtects against undercharge, restricted metering, or evaporator icing starving compressor return gas
Reset TypeManual (typically HP side), automatic (typically LP side)Manual reset on HP side is often code/insurance-required to prevent masking a dangerous fault
Setpoint RangeRefrigerant-specific pressure rangesSetpoints must match the specific refrigerant's pressure-temperature relationship
AdjustabilityFixed setpoint vs. field-adjustableAdjustable controls support field commissioning across varied system designs and refrigerants

Shop Dual Pressure Controls

Browse Dual Pressure Controls Sub-Categories

Organised by reset type and setpoint configuration. Pick a sub-category, or describe the compressor and refrigerant type and let ChatMRO match the control.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Dual Pressure Controls Get Used

Dual pressure controls are specified anywhere a refrigeration or AC compressor needs combined protection from both excessive discharge pressure and inadequate suction pressure in one control.

Commercial Refrigeration Systems

Dual pressure controls protecting refrigeration compressors from both high-side and low-side fault conditions.

Rooftop & Split AC Systems

Combined pressure switches safeguarding compressors in commercial and light industrial air conditioning equipment.

Walk-In Cooler & Freezer Units

Pressure controls preventing compressor damage from evaporator icing or condenser airflow restriction.

Process Chiller Systems

Dual pressure protection integrated into chiller compressor control and safety circuits.

Refrigerated Transport & Reefer Units

Compact dual pressure controls protecting compressor operation in mobile refrigeration equipment.

FAQ

Dual Pressure Controls Questions, Answered

What's the advantage of a dual pressure control over separate high- and low-pressure switches?

A dual pressure control combines both functions into a single body, simplifying wiring and reducing the number of components and potential failure points in the compressor's safety circuit, while still providing independent trip logic for each pressure fault. Separate switches remain an option where independent adjustability or replacement of each function is preferred.

Why is manual reset typically required on the high-pressure side but not the low-pressure side?

A high-pressure trip often indicates a condition serious enough (condenser fouling, overcharge, blocked airflow) that automatically restarting the compressor without investigation could cause repeat faults or equipment damage, which is why manual reset is frequently code- or insurance-required on the high side. Low-pressure faults, such as temporary evaporator icing, are more often self-correcting once conditions normalize, so automatic reset is more commonly accepted there.

How do I set the correct pressure setpoints for my refrigerant?

Setpoints must be selected using the specific refrigerant's pressure-temperature chart, since the same pressure reading corresponds to a different saturation temperature for different refrigerants — using setpoints calibrated for the wrong refrigerant will cause nuisance trips or, worse, fail to trip at an actually unsafe pressure.

What causes a low-pressure cutout to trip repeatedly?

Common causes include refrigerant undercharge, a restricted or failing metering device, a dirty or iced evaporator coil restricting airflow, or a failing low-pressure sensing element itself. Repeated trips should be diagnosed as a system fault first, since resetting the control repeatedly without addressing the underlying cause risks compressor damage from inadequate return gas cooling.

Can a dual pressure control be adjusted in the field, or is it fixed from the factory?

Many dual pressure controls are field-adjustable, with separate adjustment screws or dials for high- and low-side setpoints, allowing commissioning across different system designs and refrigerants. Fixed-setpoint controls are also available where a single, non-adjustable factory setpoint matches a standardized application, reducing the risk of field misadjustment.

Keep browsing

Related Categories

Explore More

Find Your Next Part Now.

Describe a part number, spec or what it does.