Arc flash clothing kits are complete PPE sets — coveralls or jacket-and-bib combinations, face shield, hood, and gloves — rated to a specific arc thermal performance value (ATPV) for protection against arc-flash incident energy. Search by cal/cm2 rating, kit contents, and standard compliance, or describe the incident energy at your equipment and let ChatMRO match the right kit.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Arc Flash Clothing Kit?

An arc flash clothing kit is a matched set of flame-resistant (FR) garments and accessories — typically coveralls or a jacket-and-bib combination, an arc-rated face shield or hood, hard hat, and voltage-rated gloves — engineered to limit burn injury from the thermal energy of an arc flash event. Every component in the kit carries an arc thermal performance value (ATPV) or energy breakopen threshold (EBT) rating in calories per square centimeter, and the kit's overall rating is the lowest-rated component in the system, so mixing an unrated or lower-rated item into an otherwise high-rated kit reduces the whole ensemble's real protection.

Kit selection should be driven by an arc flash risk assessment or incident energy analysis performed on the actual electrical equipment being worked on — per NFPA 70E, the required PPE category (and corresponding cal/cm2 rating) is determined by the calculated incident energy at the specific working distance for that equipment, not chosen generically. A kit rated well above the calculated incident energy adds unnecessary heat stress and bulk; a kit rated below it leaves a real injury gap.

Prefer a quick quote?

Get Arc Flash Clothing Kits Pricing in Your Inbox

Skip the search — tell us the required cal/cm2 rating, kit contents and sizing and we will come back with pricing.

SpecWhat It MeansWhy It Matters
ATPV/EBT RatingArc rating in cal/cm2Must meet or exceed the calculated incident energy for the specific equipment being worked
PPE CategoryNFPA 70E Category 1-4 (or specific cal rating)Determined by the equipment's arc flash risk assessment, not chosen arbitrarily
Kit CompositionCoverall vs. jacket/bib, hood/face shield, glovesOverall protection is limited by the lowest-rated component in the ensemble
Fabric TypeFR treated cotton, Nomex, PBI blendsAffects weight, heat stress, and durability across repeated arc-rated wash cycles
Standard ComplianceNFPA 70E, ASTM F1506, ASTM F2178 (face/eye)Confirms third-party tested compliance rather than a manufacturer's unverified claim

Shop Arc Flash Clothing Kits

Browse Arc Flash Clothing Kits Sub-Categories

Organised by cal/cm2 rating. Pick a sub-category, or describe the incident energy exposure and let ChatMRO match the kit.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Arc Flash Clothing Kits Get Used

Arc flash clothing kits are specified anywhere a worker performs tasks on or near energized electrical equipment with a calculated arc flash risk.

Electrical Utility & Distribution

Full arc flash suits protecting linemen and switchgear technicians working on energized distribution equipment.

Industrial Electrical Maintenance

Rated kits for technicians performing switching, testing, and troubleshooting on live panels and MCCs.

Manufacturing & Process Plants

PPE kits matched to facility arc flash studies for maintenance staff working near energized equipment.

Data Centers & Critical Facilities

Arc-rated PPE for electricians servicing UPS, switchgear, and distribution equipment under load.

Oil & Gas

High cal-rated kits for electrical work in facilities with elevated incident energy calculations.

Construction Electrical Contracting

PPE kits for electricians performing energized troubleshooting and commissioning work.

FAQ

Arc Flash Clothing Kits Questions, Answered

How do I determine what cal/cm2 rating my arc flash kit needs to be?

The required rating comes from an arc flash risk assessment or incident energy calculation performed on the specific electrical equipment, following NFPA 70E methodology — this accounts for the equipment's fault current, clearing time, and working distance to calculate incident energy at that point. The PPE category or cal rating should meet or exceed that calculated value; without a facility-specific study, NFPA 70E's table-based method can be used as an interim approach, but a calculated study is the more accurate basis.

What's the difference between ATPV and EBT ratings?

ATPV (arc thermal performance value) is the incident energy at which there's a 50% probability the fabric will transmit enough heat to cause a second-degree burn. EBT (energy breakopen threshold) applies to fabrics that can break open before reaching that burn threshold, exposing skin directly — the fabric's arc rating is reported as whichever of the two values is lower, since that's the actual point of failure.

Does the whole kit need to have a matching cal rating on every piece?

Yes, effectively — the overall protection level of an arc flash ensemble is limited by its lowest-rated component, so a 40 cal coverall paired with an unrated undershirt or a lower-rated face shield doesn't give 40 cal of actual protection. Kits are sold matched for this reason; if building an ensemble from separate pieces, confirm every component meets or exceeds the target rating.

Can I wear regular cotton or synthetic clothing under an arc flash suit?

Untreated synthetic fabrics (like polyester or nylon) should never be worn under or as part of arc flash PPE, since they can melt into the skin during an arc event even under a rated outer layer — NFPA 70E and most kit manufacturers specify FR-rated or natural-fiber (untreated cotton, wool) base layers only. Check the kit manufacturer's guidance on approved base-layer materials.

How often does arc flash PPE need to be replaced or inspected?

Arc-rated garments should be inspected before each use for damage, contamination, or wear that could compromise the fabric's protective rating, and taken out of service if torn, heavily soiled with flammable material, or after exposure to an actual arc event regardless of visible damage. Follow the manufacturer's guidance on rated wash-cycle counts and service life, since repeated laundering can degrade some FR treatments over time.