Browse by category

Temperature And Humidity Transducers

Combined temperature and relative humidity transducers with 4-20mA, 0-10V or digital output, sized by accuracy class and mounting configuration. Search by output signal and environment and let ChatMRO match the right sensor.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Temperature And Humidity Transducer?

A temperature and humidity transducer converts sensed relative humidity (RH) and temperature into a proportional electrical signal — commonly 4-20mA current loop, 0-10V voltage, or a digital protocol (Modbus, BACnet) — that a building automation system, PLC, or data logger can read. The sensing element (capacitive polymer for RH, thermistor or RTD for temperature) is exposed to the monitored air through a protective filter cap while the transmitter electronics are housed in a wall, duct, or outdoor-rated enclosure.

Accuracy is specified separately for RH (commonly ±2% to ±3% RH for standard-grade units, tighter for precision-grade) and temperature (commonly ±0.3°C to ±0.5°C), and should be selected based on the control or monitoring tolerance required by the application — cleanroom and pharmaceutical environments typically demand tighter accuracy than general HVAC comfort control. Mounting style must match the installation: duct-mount units include an insertion probe for airstream sensing, while outdoor units add a solar/rain shield and a wider operating temperature range.

Prefer a quick quote?

Get Temperature And Humidity Transducers Pricing in Your Inbox

Skip the search — tell us the output signal, accuracy needed and mounting style (wall/duct/outdoor) and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Output Signal4-20mA, 0-10V, 0-5V, Modbus/BACnet digitalMust match the controller or BMS input type it's connecting to
RH AccuracyTypically ±2% to ±3% RH standard; ±1% RH precision gradeTighter accuracy required for critical environments like cleanrooms or labs
Temperature AccuracyTypically ±0.3°C to ±0.5°CDetermines how tightly the connected control system can hold setpoint
Mounting StyleWall, duct (with insertion probe), outdoorDuct/outdoor styles need physical hardware (probe length, weather shield) matched to install location
Operating RangeStandard indoor vs. extended outdoor rangeOutdoor and extreme-environment applications need a transducer rated for the full ambient swing

Shop Temperature And Humidity Transducers

Browse Temperature And Humidity Transducers Sub-Categories

Organised by mounting configuration and accuracy class. Pick a sub-category, or tell ChatMRO the output signal and installation environment and let it match the right transducer.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Temperature And Humidity Transducers Get Used

Temperature and humidity transducers are specified anywhere RH and temperature need to feed into an automated control or monitoring system.

Building Automation & HVAC Control

Wall and duct mount transducers feed RH and temperature data into building management systems for comfort control and energy management.

Data Centers

Precision transducers monitor rack and room-level environmental conditions to protect servers from humidity and temperature excursions.

Pharmaceutical & Cleanroom Environments

High-accuracy transducers support environmental monitoring required for regulated manufacturing and storage conditions.

Greenhouse & Agricultural Monitoring

Outdoor and wide-range transducers track climate conditions for automated ventilation and irrigation control.

Warehousing & Cold Storage

Transducers monitor humidity and temperature to protect moisture-sensitive or perishable stored goods.

Industrial Process Monitoring

Duct and probe-style transducers integrate into process control loops where humidity affects product quality or process stability.

FAQ

Temperature And Humidity Transducers Questions, Answered

What output signal do I need — 4-20mA, 0-10V, or digital?

The output signal must match the input type accepted by your controller, PLC, or building automation system — 4-20mA current loop is common for longer wire runs due to its noise immunity, while 0-10V is common in shorter HVAC control runs. Digital protocols like Modbus or BACnet are used when integrating directly into a networked BMS. Confirm your controller's accepted input type before ordering.

How accurate does my humidity transducer need to be?

Standard-grade transducers (±2-3% RH) are adequate for general HVAC comfort control, while critical environments like cleanrooms, pharmaceutical storage, or data centers often specify precision-grade sensors (±1-2% RH) to hold tighter tolerances. Check your application's required control or monitoring tolerance against the transducer's published accuracy spec.

Can I use a wall-mount transducer to measure duct air temperature and humidity?

No — duct-mount transducers include an insertion probe designed to sense conditions directly within the moving airstream, while wall-mount units are designed for open room air. Using a wall-mount unit inside a duct will not give a representative reading and may not physically fit or seal the duct penetration correctly.

Do humidity sensors need periodic recalibration?

Capacitive RH sensing elements can drift over time, particularly with exposure to contaminants, condensation, or extreme humidity swings, so many facilities calibrate or verify transducers on a periodic schedule, especially in regulated or critical environments. Check the manufacturer's recommended calibration interval for your specific model.

What's different about an outdoor-rated transducer?

Outdoor transducers add a weatherproof enclosure with a solar/rain shield to prevent direct sun and precipitation from affecting the reading, along with a wider rated operating temperature range to handle seasonal extremes. A standard indoor transducer installed outdoors may read inaccurately or fail prematurely from moisture ingress.