IEC Supplementary Protectors

Miniature circuit breakers rated as supplementary protectors under IEC 60934, for equipment-level overcurrent protection inside panels and OEM machinery. Search by amperage and trip curve, or describe the load and let ChatMRO match the protector.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a IEC Supplementary Protector?

An IEC supplementary protector is a miniature circuit breaker certified to IEC 60934, intended to provide equipment-level overcurrent protection within a panel or piece of machinery that is already protected upstream by a branch-circuit-rated device — it is explicitly not rated as branch circuit protection on its own under most electrical codes, distinguishing it from a UL 489-listed circuit breaker. It's commonly used inside control panels and OEM equipment to protect individual circuits, transformers or motor branches.

Trip curve selection matters as much as amperage: a C-curve trips at 5-10x rated current, suited to general resistive and lighting loads; a D-curve trips at 10-20x rated current, tolerating the higher inrush of motors and transformers without nuisance tripping. Pole configuration (1, 2 or 3 pole) must match the circuit's phase configuration, and because supplementary protectors are not branch-circuit rated, the upstream branch protection device's rating and coordination must be confirmed separately.

Prefer a quick quote?

Get IEC Supplementary Protectors Pricing in Your Inbox

Skip the search — tell us the amperage, trip curve and pole count and we will come back with pricing.

SpecWhat It MeansWhy It Matters
StandardIEC 60934 (supplementary protector, not branch-circuit rated)Requires upstream branch circuit protection — not a standalone branch breaker under most codes
Trip CurveB, C, D curve (multiplier of rated current for instant trip)D-curve tolerates motor/transformer inrush; C-curve suits general resistive/lighting loads
Amperage RatingCommonly 0.5A to 63ASized to the protected circuit's normal full-load current, not the upstream breaker's rating
Pole Configuration1-pole, 2-pole, 3-poleMust match the circuit's phase configuration (single-phase, split-phase, three-phase)
Interrupting CapacityRated breaking capacity in kAMust exceed the available fault current at the point of installation

Shop IEC Supplementary Protectors

Browse IEC Supplementary Protectors Sub-Categories

Organised by pole configuration and trip curve. Pick a sub-category, or describe the load type and amperage and let ChatMRO match the protector.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where IEC Supplementary Protectors Get Used

IEC supplementary protectors are specified inside panels and OEM equipment wherever individual circuit protection is needed downstream of a properly rated branch circuit device.

Control Panel Circuit Protection

Protecting individual control transformer, PLC and I/O circuits within an already-protected panel.

OEM Machine Building

Equipment-level overcurrent protection built into machinery per IEC 60934, backed by upstream branch protection.

Industrial Automation Enclosures

DIN-rail mounted protectors segmenting protection for individual automation subsystems.

Lighting & Auxiliary Circuits

C-curve protectors for panel-mounted lighting and general auxiliary load circuits.

Motor Branch Circuits (Supplementary)

D-curve protectors tolerating motor starting inrush within a motor control center subcircuit.

Export/OEM Equipment for IEC Markets

Supplementary protectors specified to meet IEC-based electrical standards for equipment sold outside North America.

FAQ

IEC Supplementary Protectors Questions, Answered

What's the difference between an IEC supplementary protector and a UL 489 circuit breaker?

A UL 489-listed circuit breaker is certified for branch circuit protection and can serve as the primary overcurrent device for a circuit under the NEC. An IEC 60934 supplementary protector is tested to a different, generally less rigorous standard and is intended only to add protection downstream of an already-code-compliant branch circuit breaker — it typically cannot legally serve as the sole branch protection device in North American installations.

How do I choose between a C-curve and D-curve protector?

C-curve protectors trip instantaneously at roughly 5 to 10 times rated current, suiting general resistive and lighting loads with modest inrush. D-curve protectors tolerate 10 to 20 times rated current before instant trip, needed for motor and transformer circuits where startup inrush current would otherwise cause a C-curve breaker to nuisance-trip on every start.

Can a supplementary protector be used as the only overcurrent protection for a circuit?

Generally no, in installations governed by the NEC — supplementary protectors are explicitly not evaluated as branch-circuit protective devices, so an upstream, properly rated branch circuit breaker or fuse is still required. Using a supplementary protector as sole protection can create a code compliance and safety gap; confirm the specific application's code requirements before relying on one alone.

Does pole count need to match my supply exactly?

Yes — a single-pole protector only breaks one conductor and is used on single-phase line-to-neutral circuits; two-pole and three-pole versions break multiple conductors simultaneously for split-phase or three-phase circuits. Using a single-pole breaker where a multi-pole disconnect is required leaves one or more energized conductors unprotected or unswitched.

What does the interrupting (breaking) capacity rating mean, and why does it matter?

Interrupting capacity, rated in kA, is the maximum fault current the protector can safely interrupt without failure. If the available fault current at the installation point exceeds the protector's rated interrupting capacity, the breaker can fail catastrophically instead of safely clearing the fault — so this rating must be checked against an actual fault current calculation for the panel, not just assumed adequate.