Browse by category

Exit Device Trims

Outside trim kits for panic and fire exit hardware — lever, pull and knob styles in keyed, dummy and electrified functions, sized to rim, mortise, surface vertical rod and concealed vertical rod exit devices. Search by device series, trim function or finish.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Exit Device Trim?

An exit device trim is the outside-of-door hardware paired with a panic or fire exit device (rim, mortise, surface vertical rod, or concealed vertical rod) to give controlled entry from the exterior while the device's push bar or touchpad still allows free egress from the inside. Trim function determines what the outside lever, pull, or knob actually does: passage (always active), entry (locked/unlocked by key or cylinder), storeroom (lever always rigid, key retracts latch), or classroom function, among others.

Trim is manufacturer- and series-specific — a Von Duprin 98/99-series trim will not mount to a Sargent or Precision device without an adapter, because hole patterns, spindle engagement and through-bolt spacing differ by series. Electrified trim adds a fail-safe or fail-secure solenoid or motor, wired through the door via an electric hinge or power transfer, and must be matched to the exit device's own electrified latch retraction (ELR) or request-to-exit (REX) capability, not just the trim's own voltage rating.

Prefer a quick quote?

Get Exit Device Trims Pricing in Your Inbox

Skip the search — tell us the exit device series, trim function and door thickness and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Trim FunctionPassage, entry, storeroom, classroom, electrifiedDetermines whether the outside lever locks, and how it's keyed or powered
Device CompatibilityManufacturer/series-specific (Von Duprin, Sargent, Precision, etc.)Hole pattern and spindle engagement are not interchangeable across series without an adapter
Door PrepRim, mortise, SVR, CVR device typeTrim mounting and strike interaction differ by exit device category
FinishUS26D satin chrome, US10B oil-rubbed bronze, etc.Matches surrounding door hardware finish per ANSI/BHMA 156.18
Fire RatingUL 10C listed for fire door assembliesRequired where the trim is installed on a labeled fire exit door

Shop Exit Device Trims

Browse Exit Device Trims Sub-Categories

Organised by trim style and function. Pick a sub-category, or describe the exit device series and door prep you're matching.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Exit Device Trims Get Used

Exit device trims are specified anywhere controlled entry is needed at a door that must also satisfy panic or fire exit hardware code.

Commercial Office Buildings

Storeroom-function lever trim on rim exit devices to allow keyed entry at exterior doors while keeping free egress from within.

Educational Facilities

Classroom-function trim on stairwell and corridor exit devices to control access without impeding fire egress code compliance.

Healthcare Facilities

Electrified trim tied into access control systems for controlled entry at fire-rated egress doors.

Retail & Multi-Tenant Buildings

Keyed entry trim on rear and side exit doors, retrofit to match existing exit device series during hardware upgrades.

Government & Institutional Buildings

High-security cylinder trim paired with UL-listed fire exit devices on labeled door assemblies.

Brands

Exit Device Trims Brands in the Catalogue

Cross-reference freely between them — ask for an equivalent and ChatMRO shows what matches and what differs.

FAQ

Exit Device Trims Questions, Answered

What does 'trim function' mean on an exit device trim?

Trim function describes how the outside lever, pull, or knob behaves relative to the exit device's latch. Passage function is always unlocked; entry function is locked or unlocked by key/cylinder; storeroom function keeps the lever rigid at all times with a key required to retract the latch; classroom function allows a key to lock or unlock the outside trim while the inside bar always provides free egress. Choose the function based on the access-control need at that specific door, not just the device model.

Can I mix trim from one manufacturer with an exit device from another?

Generally no — trim mounting hole patterns, spindle engagement, and through-bolt spacing are specific to each manufacturer's device series (e.g., Von Duprin 98/99, Sargent 80, Precision Apex), so trim isn't interchangeable across brands without a documented adapter kit. Always match trim to the exact device series and, ideally, the same manufacturer.

What's the difference between electrified trim and standard keyed trim?

Standard keyed trim uses a mechanical cylinder to retract the latch. Electrified trim adds a solenoid or motor that can be triggered by an access control system (card reader, keypad, remote release), and is specified as fail-safe (unlocked on power loss) or fail-secure (locked on power loss) to match the building's life-safety and security requirements. It requires coordination with the exit device's own electrified latch retraction option and door power transfer hardware.

Do exit device trims need a fire rating?

Yes, when installed on a labeled fire door assembly, the trim must be part of a UL 10C listed combination with the specific exit device it's paired with — the fire rating applies to the tested assembly, not the trim in isolation. Always confirm the trim/device combination against the manufacturer's UL listing before specifying it for a fire-rated opening.

How do I match trim finish to existing door hardware?

Finishes follow the ANSI/BHMA 156.18 code system — for example US26D is satin chrome and US10B is oil-rubbed bronze — and matching the trim finish code to the rest of the door's hardware (hinges, closers, other exit devices) keeps appearance consistent across an opening or a building-wide retrofit.

Keep browsing