Single and three-phase buck-boost transformers for correcting voltage mismatches between supply and equipment, wired to either buck (reduce) or boost (raise) line voltage by a fixed percentage. Search by kVA rating and voltage correction range, or describe the supply and load voltages you're reconciling.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Buck Boost Transformer?

A buck-boost transformer is a standard control or distribution transformer wired autotransformer-style so its primary and secondary windings are connected in series rather than isolated, allowing it to add (boost) or subtract (buck) a fixed percentage of voltage from an incoming supply. This is used to correct chronic voltage mismatches — for example, adapting 240V supply to run 208V-rated equipment reliably, or vice versa — without the cost and size of a full isolation transformer rated for the entire load.

Because the buck-boost connection only transforms the differential voltage (not the full line voltage), a relatively small kVA-rated transformer can correct a much larger connected load — sizing is based on the voltage correction amount and load current, not the full system kVA. Selecting the wrong tap or wiring configuration can result in additive rather than subtractive voltage, so wiring diagrams must be followed exactly per the required correction direction.

Prefer a quick quote?

Get Buck Boost Transformers Pricing in Your Inbox

Skip the search — tell us the supply voltage, required output voltage and load kVA and we will come back with pricing.

SpecWhat It MeansWhy It Matters
kVA RatingSized to corrected voltage x load current, not full load kVABuck-boost only transforms the voltage differential, so a small transformer corrects a large load
Phase ConfigurationSingle-phase or three-phase (bank of 3 or pre-wired 3-phase unit)Determines wiring complexity and whether standard single-phase units can be banked for 3-phase correction
Voltage TapsMultiple primary/secondary taps for different correction percentagesAllows one transformer model to serve multiple buck or boost percentages depending on wiring
Connection TypeAutotransformer (buck-boost) vs. isolation wiringAutotransformer wiring is not electrically isolated from the supply — code and application constraints differ
Insulation ClassClass 105, 150, 180, 220 per UL/NEMADetermines maximum operating temperature rise and transformer lifespan under continuous load

Shop Buck Boost Transformers

Browse Buck Boost Transformers Sub-Categories

Organised by phase configuration and function. Pick a sub-category, or describe your supply-to-load voltage mismatch and let ChatMRO match the transformer.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Buck Boost Transformers Get Used

Buck-boost transformers are specified wherever supply voltage and equipment nameplate voltage are mismatched by a fixed, predictable percentage.

Industrial Voltage Correction

Adapting 240V facility supply to run 208V-rated motors and controls without full-load isolation transformers.

Commercial Building Retrofits

Correcting persistent under-voltage or over-voltage conditions found during equipment troubleshooting after utility service changes.

Export & Import Equipment

Adapting equipment rated for one country's nominal voltage to another's supply voltage in a cost-effective, compact package.

Lighting System Retrofits

Boosting voltage to LED or HID lighting circuits experiencing voltage drop over long conductor runs.

HVAC Equipment Installation

Correcting supply voltage to match rooftop unit and chiller nameplate ratings where building supply doesn't match equipment specification.

Data Center & Panel Upgrades

Providing small-footprint voltage correction where a full isolation transformer would not fit existing electrical room space.

FAQ

Buck Boost Transformers Questions, Answered

What is the difference between a buck-boost and a standard isolation transformer?

A buck-boost transformer is wired autotransformer-style, connecting the primary and secondary windings in series so it only adds or subtracts a percentage of voltage — it is not electrically isolated from the supply. A standard isolation transformer fully isolates primary and secondary and transforms the entire voltage, requiring a much larger kVA rating to handle the same load.

How do I size a buck-boost transformer for my application?

Size is based on the voltage correction amount (the difference between supply and required voltage) multiplied by the load current, not the full connected load kVA — this is why a small transformer can correct a large load. Manufacturer buck-boost sizing tables convert supply voltage, desired voltage and load amperage directly into the required transformer kVA.

Can I use single-phase buck-boost transformers on a three-phase system?

Yes — three single-phase buck-boost transformers are commonly banked together (wired wye or open-delta configurations per the manufacturer's diagram) to correct three-phase supply, as an alternative to a purpose-built three-phase unit. Wiring must follow the exact diagram for the intended configuration, since an incorrect connection can produce unbalanced phases.

What happens if a buck-boost transformer is wired backward?

Wiring the primary and secondary connections in the wrong configuration converts a boost connection to a buck connection (or vice versa), delivering the opposite voltage correction from what's intended — this can under- or over-voltage connected equipment. Always follow the manufacturer's wiring diagram for the specific correction direction and percentage required.

Are buck-boost transformers code-compliant for permanent installations?

Yes, when installed per the manufacturer's listed wiring diagrams and applicable electrical code, buck-boost transformers are a recognized and common method of voltage correction in commercial and industrial installations. Because they are not isolated from the supply, some jurisdictions and applications require additional grounding or disconnect considerations — verify against local code.