Isolation Transformers

Single- and three-phase isolation transformers that electrically decouple a load from its power source for safety, noise filtering, and voltage transformation. Search by kVA rating, primary/secondary voltage and phase, or describe the load and let ChatMRO match a unit.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Isolation Transformer?

An isolation transformer transfers power from primary to secondary winding through magnetic coupling with no direct electrical connection between the two, breaking the ground reference path that a load would otherwise share with the source. This protects sensitive equipment from line noise and ground loops, and, critically for safety, means a person touching one live secondary conductor while grounded does not complete a shock circuit the way they would on a directly grounded supply.

Ratings are specified in kVA (not kW) because transformer capacity is limited by heating from current flow regardless of load power factor. Electrostatically shielded units add a grounded copper shield between windings to further attenuate high-frequency noise coupling, and medical-grade units meet additional leakage-current limits under UL 60601-1 for use in patient-care areas.

Prefer a quick quote?

Get Isolation Transformers Pricing in Your Inbox

Skip the search — tell us the kVA rating, primary/secondary voltage and phase and we will come back with pricing.

SpecWhat It MeansWhy It Matters
kVA RatingContinuous power capacity, e.g. 1–75 kVAMust exceed the connected load's total apparent power with margin for inrush and future growth
Primary/Secondary Voltagee.g., 480V to 240V, 120V to 120VSets the transformer as step-up, step-down, or same-voltage isolation only
PhaseSingle phase or three phase (delta/wye)Must match the source and load phase configuration; not interchangeable
ShieldingElectrostatic (Faraday) shield, optionalReduces high-frequency noise coupling to sensitive electronic or medical loads
Temperature Rise Classe.g., 80°C, 115°C rise over 40°C ambientDetermines duty cycle and ventilation requirements in enclosed equipment

Shop Isolation Transformers

Browse Isolation Transformers Sub-Categories

Organised by phase and application. Pick a sub-category, or describe the load and voltage and let ChatMRO match a transformer.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Isolation Transformers Get Used

Isolation transformers are specified wherever electrical safety isolation, ground loop elimination, or line noise filtering is required ahead of sensitive or safety-critical loads.

Medical & Healthcare Facilities

UL 60601-compliant isolation transformers powering patient-care area equipment to limit leakage current risk.

Industrial Control & Automation

Control transformers isolating PLC and instrumentation power from noisy motor and drive circuits.

Data Centers & Sensitive Electronics

Shielded isolation transformers filtering line noise ahead of servers and precision test equipment.

Construction & Temporary Power

Portable isolation transformers providing ground-fault protection on job site temporary power drops.

Marine & Shore Power

Isolation transformers breaking the galvanic connection between shore power ground and a vessel's hull.

Laboratory & Test Equipment

Isolation transformers protecting calibration and measurement equipment from ground loop interference.

FAQ

Isolation Transformers Questions, Answered

Why is transformer capacity rated in kVA instead of kW?

kVA (apparent power) accounts for both real and reactive current draw, and it's the current — not the real power — that generates heat in the windings. A transformer must be sized to the connected load's kVA, since a low-power-factor load can draw more current, and generate more heating, than its kW rating alone would suggest.

What's the safety benefit of an isolation transformer over a standard transformer?

A standard transformer's secondary is typically still grounded and referenced to the same ground system as the primary. An isolation transformer's secondary is floated relative to ground, so a person contacting a single live secondary conductor while grounded does not complete a shock path — a fault to ground on one leg won't trip a breaker or shock a person the way a grounded system would.

Do I need a shielded (electrostatically shielded) isolation transformer?

Only if the load is sensitive to high-frequency electrical noise — servers, precision instrumentation, and audio/video equipment commonly specify shielded units. A grounded copper shield between the windings intercepts capacitively coupled noise that an unshielded transformer would pass through to the secondary.

What does 'medical grade' mean for an isolation transformer?

Medical-grade isolation transformers meet UL 60601-1 leakage current limits specifically because they may power equipment connected to a patient in a care area, where even small leakage currents pose a risk. They typically also include a line isolation monitor or are paired with one to continuously verify isolation integrity.

Can an isolation transformer also change voltage?

Yes — isolation transformers can be wound as step-up, step-down, or 1:1 (same voltage), and voltage transformation is independent of the isolation function. Specify both the required primary/secondary voltages and confirm isolation is needed, since a same-voltage isolation transformer is a distinct product from a general-purpose step transformer.