Communication Cables

Twisted-pair copper (Cat5e, Cat6, Cat6a) and fiber optic communication cables for structured data networking, sized by category rating, shielding and jacket rating for the installation environment. Search by category and shielding type, or describe the run and let ChatMRO match the right cable.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Communication Cable?

Communication cable carries structured data signals between network equipment, most commonly as twisted-pair copper (Cat5e, Cat6, Cat6a) for Ethernet runs up to 100 meters, or fiber optic (single-mode or multi-mode) for longer runs and higher bandwidth immune to electromagnetic interference. Category rating determines maximum data rate and bandwidth — Cat5e supports 1 Gbps, Cat6 supports 1 Gbps reliably to 100m and 10 Gbps to roughly 55m, and Cat6a supports 10 Gbps to the full 100m — with each higher category using tighter twist rates and often thicker conductors to reduce crosstalk at higher frequencies.

Jacket rating is a life-safety requirement, not a performance spec: plenum-rated cable uses a low-smoke, fire-retardant jacket required by code for runs through air-handling spaces like above drop ceilings used for HVAC return air, while riser-rated cable suits vertical shaft runs between floors, and outdoor/direct-burial cable adds UV and moisture resistance (and sometimes gel-filled cores) for exterior or underground runs — installing the wrong jacket rating for the space is a fire code violation, not just a durability shortfall.

Prefer a quick quote?

Get Communication Cables Pricing in Your Inbox

Skip the search — tell us the category rating, shielding requirement and jacket rating (plenum/riser/outdoor) and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Category RatingCat5e, Cat6, Cat6aDetermines maximum supported data rate and distance — Cat6a needed for 10 Gbps at full 100m runs
ShieldingUTP (unshielded) vs. STP/FTP (shielded)Shielded cable resists EMI in industrial or high-interference environments; unshielded is standard for typical office use
Jacket RatingPlenum (CMP), riser (CMR), outdoor/direct burialPlenum required by fire code for air-handling spaces; wrong rating for the space is a code violation
Conductor TypeSolid (fixed runs) vs. stranded (patch cords)Solid conductor suits permanent in-wall runs; stranded suits flexible patch cables that see repeated flexing
Fiber TypeSingle-mode (long distance) vs. multi-mode (shorter, cost-effective)Single-mode supports much longer runs at higher bandwidth but requires more precise, costlier optics

Shop Communication Cables

Browse Communication Cables Sub-Categories

Organised by cable category and jacket rating. Pick a sub-category, or describe the network run and environment and let ChatMRO match the cable.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Communication Cables Get Used

Communication cables are specified anywhere network equipment needs a reliable, code-compliant physical data connection.

Commercial Office Networking

Structured Cat6 cabling for office data drops and network infrastructure.

Data Centers

High-bandwidth Cat6a and fiber optic cabling between server racks and network equipment.

Industrial Automation Networks

Shielded communication cable resisting EMI from motors and variable frequency drives on the plant floor.

Campus & Building-to-Building Networking

Fiber optic cable for long-distance, interference-immune links between buildings.

Security & Surveillance Systems

Network cabling for IP camera and access control system connectivity.

Telecommunications Infrastructure

Structured cabling supporting voice, data and building automation systems.

FAQ

Communication Cables Questions, Answered

What's the difference between Cat5e, Cat6 and Cat6a cable?

Cat5e reliably supports 1 Gbps Ethernet. Cat6 supports 1 Gbps to the full 100 meters and can support 10 Gbps up to about 55 meters. Cat6a supports 10 Gbps across the full 100-meter run, using tighter construction and often thicker conductors to control crosstalk at the higher frequencies 10 Gbps requires.

Do I need plenum-rated cable for my installation?

If the cable runs through an air-handling space — most commonly above a drop ceiling used as HVAC return air plenum — building and fire code requires plenum-rated (CMP) cable with a low-smoke, fire-retardant jacket. Using riser or general-purpose cable in a plenum space is a code violation, not just a durability issue.

When should I use shielded (STP) cable instead of unshielded (UTP)?

Shielded cable is worth the added cost in environments with significant electromagnetic interference — near large motors, variable frequency drives, or other industrial equipment — where unshielded cable's signal could be degraded by EMI. Standard office environments typically don't need shielded cable.

What's the difference between single-mode and multi-mode fiber?

Single-mode fiber uses a much narrower core and a laser light source, supporting significantly longer runs (kilometers) at high bandwidth, but requires more precise and expensive optics. Multi-mode fiber uses a wider core and LED or VCSEL light sources, is less expensive, and suits shorter runs typical within a building or campus.

Can I use stranded patch cable for a permanent in-wall run?

It's not recommended — stranded conductor cable is designed for flexibility in patch cords that get moved and flexed repeatedly, but it doesn't terminate as reliably in punch-down connections and isn't rated for the same performance over permanent link distances. Solid conductor cable is the standard for fixed in-wall or in-ceiling runs.