Browse by category

Air Velocity Indicators

Vane, hot-wire and rotating vane anemometers for measuring air velocity and volumetric flow in ducts, at diffusers and in open-area airflow. Search by sensor type, velocity range and duct size, or describe the airflow measurement you're taking.

  • 30M+ parts indexed
  • Procure in < 60 seconds
  • No credit card required

Searchable by Spec

Indexed on full specifications rather than titles alone, so a spec can be searched directly.

Backed by Raptor Supplies

The same suppliers, pricing desk and people standing behind every quote.

US & Worldwide

Serving the US, with fulfilment across the UK, EU, Singapore and Australia.

Technical Foundation

What Is a Air Velocity Indicator?

An air velocity indicator (anemometer) measures the speed of moving air and, when paired with a known duct or opening area, calculates volumetric airflow (CFM or m³/h). Rotating vane anemometers use a small propeller whose spin rate is proportional to air velocity — robust and simple, but with a lower sensitivity limit that struggles at very low velocities. Hot-wire (thermal) anemometers instead measure the cooling effect of airflow on a heated sensor element, giving much better sensitivity at low velocities but requiring more careful handling of the delicate sensor.

Sensor selection depends on the velocity range and location being measured: high-velocity duct traverses favor a vane or Pitot-based instrument, while low-velocity diffuser or room airflow readings favor a hot-wire probe. Accuracy at any given point also depends on correct probe placement relative to turbulence and duct geometry — most instruments specify a minimum straight duct run before and after the measurement point to get a representative reading.

Prefer a quick quote?

Get Air Velocity Indicators Pricing in Your Inbox

Skip the search — tell us the velocity range, sensor type and probe length and we will come back with pricing.

SpecWhat It MeansWhy It Matters
Sensor TypeRotating vane, hot-wire (thermal), Pitot-basedVane suits higher velocities; hot-wire is more sensitive at low velocities
Velocity RangeCommonly 0-datasheet-specific max, in ft/min or m/sMust cover the expected range at both the low and high end of the application
Probe ConfigurationHandheld head, telescoping duct probe, flow hoodDetermines how the sensor is positioned relative to the airflow being measured
Accuracy & ResolutionTypically ±3-5% of reading, per datasheetDetermines suitability for code-required balancing vs. general troubleshooting
Data LoggingSingle reading, averaging, logging to memory/PCLogging supports documented balancing reports and trend analysis

Shop Air Velocity Indicators

Browse Air Velocity Indicators Sub-Categories

Organised by sensor type. Pick a sub-category, or describe the velocity range and application and let ChatMRO match the instrument.

How it works

From Half-Remembered Part Number to PO, in Three Steps.

01

Ask

Type an MPN, paste a spec sheet, or describe the part in plain English. ChatMRO understands engineer-speak.

02

Compare

Side-by-side specs, cross-references, and equivalents from multiple sources — without the clutter of endless browser tabs.

03

Quote & Buy

Request a quote or add to cart. Volume discounts, VAT-aware pricing, and consolidated procurement — all in one place.

Applications

Where Air Velocity Indicators Get Used

Air velocity indicators are specified anywhere airflow needs to be measured and verified against a design or code requirement.

HVAC Testing, Adjusting & Balancing (TAB)

Measuring supply and return air velocity at diffusers and ducts to balance airflow across a building's zones.

Industrial Ventilation & Fume Hood Testing

Verifying face velocity at fume hoods and local exhaust ventilation points meets safety code minimums.

Cleanroom & Laminar Flow Verification

Confirming uniform low-velocity airflow across HEPA-filtered ceiling grids in cleanroom environments.

Energy Audits & Building Commissioning

Documenting airflow rates against design specifications during new construction or retrofit commissioning.

Agricultural & Livestock Ventilation

Checking fan and vent airflow rates in barns and greenhouses to maintain proper air exchange rates.

FAQ

Air Velocity Indicators Questions, Answered

Should I choose a vane or hot-wire anemometer?

Rotating vane anemometers are more durable and cost-effective for general HVAC duct and diffuser measurements at moderate to high velocities. Hot-wire (thermal) anemometers offer better sensitivity at low velocities — useful for fume hood face velocity, laminar flow benches, or low-flow diffusers — but the sensor element is more delicate and typically costs more.

How does an anemometer calculate CFM from velocity?

The instrument (or the technician, using the reading) multiplies measured air velocity by the cross-sectional area of the duct or opening being tested: CFM = velocity (ft/min) × area (sq ft). Many digital anemometers let you enter the duct or diffuser area directly and calculate CFM automatically, which is faster and reduces manual calculation error during balancing work.

What's a duct traverse and why does it matter?

Air velocity varies across a duct's cross-section due to friction near the walls and turbulence, so a single center-point reading can misrepresent average velocity. A duct traverse takes multiple readings at defined grid points across the duct and averages them, giving a more accurate airflow figure — most balancing standards specify the traverse point pattern and minimum straight duct run required.

How accurate do anemometers need to be for code-required balancing?

Requirements vary by project and governing standard (such as AABC or NEBB balancing procedures), but instruments used for documented, code-required TAB reports typically need a stated accuracy of ±3-5% of reading along with a current calibration certificate. General troubleshooting or comfort checks don't require the same documented accuracy.

Can the same anemometer measure both duct and open-area airflow?

Many handheld units can do both with an appropriate probe attachment — a telescoping probe for duct insertion and a bare vane or hot-wire head for open-area or diffuser-face readings. Confirm the probe options available for a given instrument model match both the duct sizes and the open-area conditions you need to measure.