Kidde Fire Alarm Pull Station Sourcing

The fastest way to find, compare and buy Kidde fire alarm pull stations.

Describe your alarm panel type, action style, or mounting need. ChatMRO finds the exact Kidde match, shows alternatives, and gives you a quote — in seconds. No part number needed.

  • 30M+ parts indexed
  • Quote in < 60 seconds
  • No credit card required
  • No exact MPN needed
Technical Foundation

What is a Kidde fire alarm pull station — and why does the K-270 dominate conventional manual initiation?

A fire alarm pull station is a manual initiating device: an occupant pulls a handle, or breaks the glass and operates the lever, to send an alarm signal to the fire alarm control panel. Unlike smoke and heat detectors, it needs a person to act. After operation, most pull stations must be reset with a key or special tool before the panel can be reset. Kidde Commercial's K-270 Series is a conventional, non-coded, single-action break-glass station with a pull lever and a solid die-cast metal housing, designed for economical installation.

Building owners, facilities managers, and fire alarm contractors specify Kidde pull stations where a manual alarm point is required. The key choices are the type of system (conventional or addressable), the action (single or double), the contact configuration, and how the station connects to the circuit. The K-270 series is available with normally open, normally closed, or combined NO/NC contacts, and Kidde states its pull force is under 5 lb, which complies with ADA. Always confirm panel compatibility and code requirements with your fire alarm panel documentation and the authority having jurisdiction.

Common configuration for the K-270 series: a red die-cast metal station, about 4-1/2" H x 3-1/4" W x 2-1/2" D on the K-270A-DPO listing, for flush or surface mounting. The basic K-270 has screw terminals, while the K-270A versions have 6" (150 mm) wire leads. Flush mounting uses a 4" standard North American square box with a single-gang plaster cover. The K-270A-SPO is listed as single-pole with a 30 VAC / 60 VDC rating and a 3 A contact rating, while the K-270A-DPO is a double-pole (DPST-NO) station listed with 0.5 A at 250V AC/DC and 1.5 A at 125V AC/DC for 24V DC / 125V AC conventional systems. The K-270A-DPO listing also cites UL and CSFM standards, 95% RH humidity range, and 0.3 lb weight. Other Kidde families include the plastic K-277B, the GSA-M270/M278 Signature Series, and the FX-270/FX-278 intelligent addressable stations.

Quick-Reference Spec Glossary

Operation
Single-action, break-glass, pull-lever (K-270 series)
Contact options
NO, NC, or combined NO/NC; single-pole (SPO) or double-pole (DPO) variants
Field connection
Screw terminals (K-270) or 6" (150 mm) wire leads (K-270A)
Mounting
Flush (4" square box with single-gang plaster cover) or surface
Dimensions (K-270A-DPO listing)
4-1/2" H x 3-1/4" W x 2-1/2" D
Ratings
K-270A-SPO: 30 VAC / 60 VDC, 3 A contacts; K-270A-DPO: 0.5 A @ 250V, 1.5 A @ 125V AC/DC
Housing
Solid die-cast metal (K-270 series); plastic on the K-277B
Compliance
UL and CSFM on the K-270A-DPO listing; pull force under 5 lb (ADA)
Procurement Decision Tool

Which Kidde pull station configuration is right for your application?

Stop second-guessing. Match your use case below — then let ChatMRO's AI surface the exact model, system type, and alternatives in one natural-language search.

Addressable & Double-Action Systems

Intelligent or module-address systems, and installations that want to reduce accidental pulls. The GSA-M278 and FX-278 dominate here.

  • Double action: lift the door marked "LIFT THEN PULL HANDLE," then pull the handle
  • GSA-M278 is red Lexan, UL/ULC listed, and uses a module address
  • FX-270 (single) and FX-278 (double) are for Kidde FX-64 and FX-1000 intelligent systems
  • Addressable stations need the control panel's electrical power to operate
Find on ChatMRO →

Pre-Signal & Specialty Applications

Systems with a pre-signal stage, or suppression release use.

  • K-270P is a break-glass, normally open pre-signal station
  • Pulling the lever sounds pre-signal devices, and a key turn starts a general evacuation alarm
  • Kidde Series 3300 stations can be field-labeled for fire alarm or suppression release
  • Confirm labeling and listing for your application
Find on ChatMRO →

Not sure which category fits? Just describe your problem

No MPN required. No filter trees. Just ask.

Brand Intelligence

Products — What to choose and whyKIDDE

Kidde's pull station range spans conventional K-270 stations and addressable GSA and FX families. Here's how to navigate it without a 40-tab browser session.

ChatMRO indexes the full Kidde manual pull station catalogue. Search any product by description, application, or rough spec.

CONVENTIONAL, SINGLE ACTION
K-270 / K-270A Series

Kidde K-270 Series Non-Coded Break-Glass Pull Stations

The conventional workhorse. Single-action break-glass pull lever, die-cast metal housing, NO/NC/combined contacts. K-270A versions have 6" wire leads; the K-270A-SPO is single-pole at 30 VAC / 60 VDC and the K-270A-DPO is double-pole. Flush or surface mount.

  • Single Action
  • Die-Cast Metal
  • SPO or DPO
  • Wire Leads
Search K-270 / K-270A Series →
ADDRESSABLE, DOUBLE ACTION
GSA-M270 / GSA-M278 Series

Kidde Signature Series Manual Pull Stations

Part of Kidde's Signature Series. The GSA-M270 has the familiar teardrop shape, and the GSA-M278 is a double-action, one-stage station in red Lexan that uses a module address. UL/ULC listed.

  • Addressable
  • Double Action (M278)
  • Lexan
  • UL/ULC Listed
Search GSA-M270 / GSA-M278 Series →
INTELLIGENT SYSTEMS
FX-270 / FX-278 Series

Kidde Addressable Intelligent Manual Pull Stations

For Kidde FX-64 and FX-1000 intelligent systems. The FX-270 requires one action and the FX-278 requires two (lift the door, then pull the handle). Both are normally open dry contact initiating devices with alarm latching and meet ADA requirements.

  • FX-64 / FX-1000
  • Single or Double Action
  • Alarm Latching
Search FX-270 / FX-278 Series →
Side-by-Side Comparison

Kidde pull station options — when to choose what

Use this table as a decision shortcut. Ask ChatMRO for the exact part once you know which row fits your spec.

ModelActionSystem TypeHousingConnection / ContactsBest ForChatMRO Verdict
K-270A-SPOSingle, break glassConventionalDie-cast metal6" wire leads, single pole, 30 VAC / 60 VDCStandard conventional initiating circuitsMost common choice for conventional single-action replacement
K-270A-DPOSingle, break glassConventional (24V DC / 125V AC listing)Die-cast metalWire leads, double pole (DPST-NO)Circuits that need a second contact setUse when a double-pole contact is required
K-277B-1120Single, break glassConventionalPlasticWire leads, single pole, key resetPlastic-housing alternativeConsider when a plastic housing is preferred
GSA-M278Double (lift door, then pull)Addressable (module address)Red LexanUses module addressAddressable systems that want fewer accidental pullsGo-to for double-action addressable installs
FX-278DoubleKidde FX-64 / FX-1000 intelligentModel-specificNormally open dry contactKidde FX intelligent systemsUse with FX panels; FX-270 is the single-action version
Generic Import Pull StationVariableVariableVariableVariableBudget, occasional light useVerify UL listing and panel compatibility before installing on a life-safety system

Not sure which row is yours? Describe your application to ChatMRO and get an instant AI-matched recommendation with datasheets.

How ChatMRO AI Works

Stop filtering. Start asking. AI-powered part discovery for MRO.

Traditional catalogues force you to know the exact MPN before you find anything. ChatMRO flips that: describe what you need in plain English, and the AI finds the right pull station from 30M+ indexed parts.

  1. 01

    You describe the part

    In plain language — by panel type, action style, or mounting need. No MPN required.

  2. 02

    AI matches semantically

    Natural language processing maps your description to the closest-fit products across brands and specs.

  3. 03

    Alternatives surface instantly

    Cross-brand equivalents, lower-cost substitutes, and in-stock alternatives shown side-by-side.

  4. 04

    Quote in 60 seconds

    Add to cart or request RFQ directly from the results. No phone calls. No email chains.

Buyer's Technical Guide

How to select the right Kidde fire alarm pull station

Whether you're a facilities manager replacing damaged stations, or a fire alarm contractor specifying devices for a new system — use this framework before you procure.

5-Step Selection Checklist

  1. 1

    Match the system type and panel

    Confirm whether your panel is conventional or addressable. Conventional systems use stations like the K-270 series, while addressable systems use stations such as the GSA-M278 or the FX-270/FX-278. Check your panel documentation for compatibility.

  2. 2

    Choose single or double action

    Single-action stations activate with one pull. Double-action stations such as the GSA-M278 and FX-278 require lifting the door marked "LIFT THEN PULL HANDLE" first, which reduces accidental activations.

  3. 3

    Select contact configuration and connection style

    K-270 stations come with NO, NC, or combined NO/NC contacts, in single-pole or double-pole versions. Choose screw terminals (K-270) or 6" wire leads (K-270A) and check the voltage and contact ratings against your circuit.

  4. 4

    Plan the mounting

    Stations mount flush or on the surface. For flush mounting, use a 4" standard North American square box with a single-gang plaster cover, and follow local code on mounting height and pull force.

  5. 5

    Confirm listings and reset procedure

    Check the listings your jurisdiction requires (for example UL, UL/ULC, or CSFM) and plan for key reset after operation. Confirm requirements with the authority having jurisdiction.

Common Procurement Mistakes

  • Ordering without matching conventional vs. addressable

    A conventional station and an addressable station are not interchangeable. Search by function on ChatMRO — the AI surfaces exact matches AND available substitutes compatible with your panel.

  • Overlooking voltage and contact ratings

    Ratings differ between models, for example 30 VAC / 60 VDC on the K-270A-SPO versus 0.5 A at 250V on the K-270A-DPO listing. Check them against your initiating circuit.

  • Not planning for key reset

    Pull stations generally must be reset with a key or special tool after operation, so make sure the right key or tool is available to building staff.

  • Spending hours in supplier catalogues

    Describing your application to ChatMRO takes 30 seconds. The AI reads the full Kidde pull station catalogue so you don't have to.

FAQ — Kidde Fire Alarm Pull Station

Questions facilities managers and procurement teams ask most

What's the difference between single-action and double-action pull stations?

A single-action station sounds the alarm with one pull of the handle, while a double-action station requires two actions: lift the upper door marked "LIFT THEN PULL HANDLE," then pull the handle. Kidde's GSA-M278 and FX-278 are double action. Search both styles on ChatMRO to compare pricing and availability instantly.

What's the difference between conventional and addressable Kidde stations?

Conventional stations like the K-270 series connect to initiating device circuits on a conventional panel, while addressable stations such as the GSA-M278 (module address) and the FX-270/FX-278 (for Kidde FX-64 and FX-1000 systems) report to an intelligent panel. ChatMRO can surface stations for your panel type from a single description search.

What does the K-270 versus K-270A suffix mean, and what are SPO and DPO?

The basic K-270 has screw terminals for field connection, while the K-270A has 6-inch (150 mm) wire leads. SPO denotes a single-pole station and DPO a double-pole station. ChatMRO provides access to manufacturer specification details directly from search results.

How are these stations mounted and reset?

They mount flush on a 4-inch standard North American square box with a single-gang plaster cover, or on the surface with a suitable box, and listed K-270A stations are manually reset with a key tool after operation. If you're unsure which station fits your system, describe your application to ChatMRO and get an AI recommendation in seconds.

Where can I buy a Kidde fire alarm pull station with fast delivery?

ChatMRO indexes Kidde inventory from multiple distributors across India, Southeast Asia, US, and EU. Search by part name, description, or rough spec — you'll see real-time stock levels and can request a quote in under 60 seconds without calling a single distributor.

I don't know the exact model number — can I still find it?

Yes — that's exactly what ChatMRO is built for. Describe your panel type, action style, and mounting need in plain English. The AI matches your description against 30M+ indexed parts and returns the closest Kidde SKU with datasheet, alternatives, and a quote option. Try it now — no account required.

Don't know the model number? No problem.

Just describe what you need. ChatMRO finds the right Kidde fire alarm pull station in seconds.

Kidde Fire Alarm Pull Stations — Sourcing Intelligence for Industrial Buyers

Kidde fire alarm pull stations are widely specified manual initiating devices for commercial, institutional, and industrial buildings. Kidde commands significant market presence with its K-270 series conventional break-glass stations in die-cast metal, the plastic K-277B, and addressable GSA-M270/M278 and FX-270/FX-278 families, offering single- and double-action operation and a range of contact and connection options. Procurement professionals and fire alarm contractors in India, Southeast Asia, and North America regularly source Kidde pull stations for replacement, new installations, and facility life-safety upgrades.

ChatMRO simplifies this procurement process by providing AI-powered natural language search across a catalogue of 30 million+ indexed industrial parts. Buyers no longer need to memorize model codes or navigate multi-level filter trees to find the right pull station. A simple description of the panel type, action style, or mounting need is sufficient to surface the correct Kidde product alongside cross-brand alternatives and real-time pricing.

Explore More