Range50.8 mm
Display7-digit display, sign, and analog bar
Resolution0.0005/0.001/0.01 (selectable) mm
Battery LifeApprox. 2,700 hours of continuous use. Approx. 2.5 years under normal use.
Power SourceCR2032 battery (1 pc.), included as standard (for operational checks)
Mass Flat Back260 g
Response SpeedUnlimited (except for scanning measurement)
Spindle Orientation for MeasurementUsable between the contact point pointing downward and spindle in horizontal orientation. To use the contact point pointing upward, the auxiliary spindle spring (optional) is required.
Maximum Permissible Error Hysteresis0.002 mm
Maximum Permissible Limit Measuring Force2.3 or less N
Maximum Permissible Error Repeatability0.002 mm
Maximum Permissible Error Total Measuring Range0.005 mm
Maximum Permissible Error Partial Measuring Range0.005 mm
Back TypeFlat
IncludesCR2032 Battery
Display TypeLCD
Unit of MeasureMetric
Measurement Range50.80 mm
Batteries IncludedYes
Contact Point MaterialCarbide
Minimum Measurement0.00 mm
Connection TypeStraight