Sensor length6.7"
Cable length40 ft.
Output amps4-20 mA
Power required13-30V DC
Operating temp. range0°F to +150°F
Pressure range0 psi to 10 psi
Pressure rating0 psi to 10 psi
Cable coatingPolyurathane
TypeBullet Nose
Output4-20 mA
Process connection size1/2"
Cable materialPolyurethane
Connection typeNPT
Electrical protectionYes
GradeGrade 316
Housing materialStainless Steel
Sensor dia.1"
Standard logoCE.png
Measuring depth0 ft. to 23.1 ft.
Manufacturers warranty length1 yr.
Minimum pressure0 psi
SeriesSBLT2 Series
Thermal error-0.02% to +0.02%
Accuracy±0.25% of Full Scale
Electrical connectionsCable & Wire Leads
Seal materialFluoroelastomer
Tip designBullet Nose
Maximum operating temperature150°F
Minimum operating temperature0°F
Overall height7.187"
Maximum loop resistance900 ohms
Maximum pressure10 psi
Response time50 ms
Pressure range-submersible transmitter0 psi to 10 psi
Pressure0 psi to 10 psi
Mfr. seriesSblt2
IncludedInstruction
Supply voltage13-30 VDC
Body styleSubmersible
Ip ratingIP66
Measurement range23.09 ft
Mounting typeHanging
Sensing modePiezoresistive
TerminationCable
Temperature limitSBLT2: Polyurethane: 0 to 150°F (-18 to 66°C); ETFE: 0 to200°F (-18 to 93°C); SBLTX -4 to 176°F (-20 to 80°C); Polyurethane: -4 to 149°F(-20 to 65°C).
Wetted materialsBody: 316 SS, 316L SS; Bullet nose: PVC; Cable: Polyether polyurethane or ETFE; Seals: Fluoroelastomer.
ServiceCompatible liquids.
Mounting orientationSuspended in tank below level being measured.
Max. loop resistance900 Ω at 30 VDC.
ComplianceSBLT2: CE; SBLTX: CE, cULus intrinsically safe for Class I,Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III Div. 1; ATEX: II1 G Ex ia IIC T4 Ga and II 1 D Ex ia IIIC T135C Da (according to control drawing001833-43)*.
Output signal4 to 20 mA DC, 2-wire.
Power requirementSBLT2: 10 to 30 VDC (≤1000 ft (305 m) of cable); SBLTX: 10 to 28 VDC.
Pressure limit2X FS.
Thermal effect±0.02% full scale/°F.
Compensated temperature rangeSBLT2: 0 to 140°F (-18 to 60°C); SBLTX: 0 to 176°F (-18 to 80°C).