Standard logofm.png,ce.png,rohs.png
Range314 2/5"
Deadband8"
Output signal4-20 mA
Operating temp. range-4°F to +140°F
Motor enclosure designNEMA 4
Hazardous location specificationClass I, DIV 1, Group A, B, C, D, Class Ii, DIV 1, Group E, F, G
MaterialPVDF
Max. pressure30 psi
ConfigurationPush Button
Pump typeExplosion Proof Pump
Operating frequency50 kHz
Beam width3"
ClassificationExplosion Proof
Media typeCorrosive Liquid, Sticky/Waste Liquid
Connection typeNPT
Gasket materialViton
Display typeLCD
No. of digits6
Overall dia.4"
Resolution0.079"
Antenna dia.2 3/8"
Output wire configuration2
Enclosure materialAluminum
Connection size2"
Overall width4"
Overall height6.1"
Dead band8"
Spatial resolution0.079"
Antenna diameter2 3/8"
Max. operating pressure30 psi
For media typeCorrosive Liquid, Sticky/Waste Liquid
Media temp. range-4°F to +140°F
Output voltage range4-20 mA
Media temperature (minimum)-4°F
Accuracy±0.2% of Range
Connection2" NPT
Max. media temperature140°F
Max. voltage28V DC
Enclosure ratingNEMA 4X
Transmitter typeUltrasonic Explosion-Proof Transmitter
Minimum operating temperature-40 F
Mount size2" NPT
Measuring depth26.2 ft
Sensor length4 in
EnvironmentHazardous Location
Body materialAluminum
For use withCorrosive, Sticky or Waste Liquid
StandardsCE; FM; RoHS
Unspsc code41111938