Output signal4-20 mA
Accuracy-5% to +5%
Communication methodAnalog Universal
Wire size16 AWG to 26 AWG
Mounting orientationParellel
Response time10 sec.
Max. current60 mA
Power requirement24V AC/DC
Display digits5
Relative humidity range5% rh to 95% rh
Relative humidity typeNon Condensing
Connection size1/2"
Connection typeNPS
Device load1/8th Unit Load
Display typeLCD
Electrical connectionAnalog
Zero & span adjustmentsDigital Push Buttons
Load resistance max.0 ohms to 1100 ohms
Temp. limit (deg. f)+32°F to +122°F
Enclosure ratingNEMA 4X
Probe dia.0.47"
Air velocity accuracy-5% to +5%
Dia.15/32"
Probe length7 41/64"
Max. dc voltage required24V
Minimum output signal4 mA
Maximum ac voltage required24V
Maximum output signal20 mA
Communication protocolUniversal
Max. temp. measuredNot Applicable
Digital display screen typeNo Display
Max. probe length7 16/25"
Min. operating temp.Not Applicable
Manufacturer warranty length1 yr.
Air velocity measured1000-4000 FPM
Calibration certificateNot Included
Maximum operating temperature122°F
Minimum temperature measured32°F
Operating temperature122°F
Maximum velocity measured4000 FPM
Minimum velocity measured1000 FPM
Maximum probe length7.64"
Wetted materialsConsult factory.
ServiceClean air and non-combustible, compatible gases.
Temperature range32 to 122°F (0 to 50°C).
Air velocity range1000, 2000, 3000, 4000 FPM (5, 10, 15, 20 m/s); field selectable.
ComplianceBTL, CE.
Electrical entry1/2" NPS thread. Accessory: Cable gland for 5 to 10 mm diameter cable, A-151.
CommunicationConnections: BACnet MS/TP or Modbus® RTU/ASCII: three wire removable European style terminal block for 16 to 26 AWG; Supported baud rates: 9600, 19200, 38400, 57600, 76800, 115200. (optional)
Electrical connectionsAnalog; power and output: four wire removable European style terminal block for 16 to 26 AWG.
Display5 digit LCD (optional).
Current consumption60 mA max.
Output load resistanceCurrent output: 0 to 1100 Ω max.; Voltage output: Minimum load resistance 1 kΩ.
Response time (90%)10 s, typical.
Output signals4 to 20 mA, 0 to 5 VDC, 0 to 10 VDC.
Humidity limits.5 to 95% RH, non-condensing.
Power requirements24 VDC ±20% or 24 VAC ±20%.
Temperature limits32 to 122°F (0 to 50°C).
Range1000, 2000, 3000, 4000 FPM (5, 10, 15, 20 m/s); field selectable.
Temperature unitsDegree C, Degree F
Gross weight0.85 lbs
Air temperature (f)32-122 °F
Air velocity ft/min1,000-4,000
Air velocity m/s5-20
Humidity range5-95 %
Basic accuracy5 %
Family seriesDwyer Instruments Anemometers, AVUL Series
Ships factory directNo
Product seriesAVUL